Skip to specifications
versus.deals
Menu
Browse versus.deals
HEAT PUMPS

LG HN1616Y NB1 + HU143MRB U30

UK configuration

Exact manufacturer unit purpose
R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Manufacturer heating capacities at separate operating points
11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7)

LG HN1616Y NB1 + HU143MRB U30 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG HN1616Y NB1 + HU143MRB U30 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG HN1616Y NB1 + HU141MRB U30

Specifications checked 19 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked heat pumps by key specifications, with what differs from the LG HN1616Y NB1 + HU143MRB U30. The first matches the Compare button above.

Front view of R32 Monobloc S, 1Ø, 5kW HM051MR U44LG HM051MR U44UK manufacturer configuration · HM051MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 5kW HM051MR U44This one: R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Manufacturer heating capacities at separate operating points
4.40 kW (A+2/W+35); 5.50 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)
Front view of R32 Monobloc S, 1Ø, 7kW HM071MR U44LG HM071MR U44UK manufacturer configuration · HM071MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 7kW HM071MR U44This one: R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Manufacturer heating capacities at separate operating points
5.60 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)
The useful part.

Key strengths

The official LG UK page identifies manufacturer model HN1616Y NB1 + HU143MRB U30.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · HN1616Y NB1 + HU143MRB U30

49 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 11 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

22 items
Manufacturer heating capacities at separate operating points
11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — Heating capacity (kW): 11.50; NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): -25 ~ 35; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15 ~ 65. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer efficiency declarations and source methods
COP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — COP: 2.85; NOMINAL CAPACITY AND COP (A-7/W+55) — COP: 2.60; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.63; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.89; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 4.30; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 5 ~ 48; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 5 ~ 27; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 180 / 136; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.57 / 3.47; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 120; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
NOMINAL CAPACITY AND COP (A-7/W+35) — Heating capacity (kW)
11.50Source
NOMINAL CAPACITY AND COP (A-7/W+35) — COP
2.85Source
NOMINAL CAPACITY AND COP (A-7/W+55) — COP
2.60Source
NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW)
14.00Source
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
3.63Source
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
12.00Source
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
4.89Source
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
4.30Source
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
-25 ~ 35Source
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
5 ~ 48Source
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
15 ~ 65Source
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
5 ~ 27Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
180 / 136Source
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
4.57 / 3.47Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
A+++/A++Source
WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate
120Source
WATER HEATING EFFICIENCY DATA — COPDHW, average climate
2.74Source
WATER HEATING EFFICIENCY DATA — Declared load profile, average climate
LSource
WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate
A+Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
14.00Source
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
14.00Source

Refrigerant & circuit

2 items
Manufacturer refrigerant type
Male PT 1"

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: Male PT 1". Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
REFRIGERANT — GWP
Female G1"Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

REFRIGERANT — Precharged amount (g)
Female G1"Source
REFRIGERANT — Type
Male PT 1"Source

Electrical supply & consumption

1 item
Manufacturer electrical supply requirements
220-240, 1, 50

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
220-240, 1, 50Source

Installation, dimensions & airflow

15 items
Exact manufacturer unit purpose
R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
DIMENSIONS — Indoor unit (W × H × D) (mm)
490 × 850 × 315Source
DIMENSIONS — Outdoor unit (W × H × D) (mm)
950 x 1,380 x 330Source
EXTERIOR — Indoor unit (Color / RAL code)
Noble white / RAL 9016Source
EXTERIOR — Outdoor unit (Color / RAL code)
Warm gray / RAL 7044Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))
Female G3/4"Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)
62 / 60Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)
43Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)
35Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)
40 / 38Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for DHW (inch)
91.7Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for DHW (inch)
130.0Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)
601 × 1,812 × 685Source
WEIGHT — Indoor unit (Empty) (kg)
40.5Source
WEIGHT — Outdoor unit (Empty) (kg)
84.8Source
Manufacturer wording (4)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm))

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))
Female G3/4"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)
950 × 1,380 × 330Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)
Warm gray / RAL 7044Source

Operating conditions & sound

9 items
Manufacturer sound declarations and measurement methods
380-415, 3, 50; White / RAL 9002; 44 dB(A); 63 / 61

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 380-415, 3, 50; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): White / RAL 9002; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 63 / 61. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
2,100Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
675Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
R32Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
15 ~ 80Source
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))
380-415, 3, 50Source
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
White / RAL 9002Source
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))
44Source
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
63 / 61Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer operating ranges and conditions
2,100; Male PT 1"; 675; R32; 15 ~ 80

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 2,100; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): Male PT 1"; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 675; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): R32; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Male PT 1"Source
Similar products.

Compare with another heat pumps product

More of the nearest checked heat pumps by key specifications, for a side-by-side comparison.