Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HN1616Y NB1 + HU141MRB U30 vs LG HN1616Y NB1 + HU143MRB U30

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HN1616Y NB1 + HU141MRB U30

UK manufacturer configuration · HN1616Y NB1 + HU141MRB U30

Front view of R32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30
Exact model & source notes

LG HN1616Y NB1 + HU141MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))220-240, 1, 50380-415, 3, 50
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))3644
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))41 / 3963 / 61
3 of 5 verified differences, in the order listed below. Not a rating.
See the 5 verified differences
THE CONTENDER

LG HN1616Y NB1 + HU143MRB U30

UK manufacturer configuration · HN1616Y NB1 + HU143MRB U30

Front view of R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Exact model & source notes

LG HN1616Y NB1 + HU143MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HU141MRB U30 UK & US retailers

UK & US price history: no verified listing yet

HU143MRB U30 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE5 topics
SELECTED TOPIC
01 / 05

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HN1616Y NB1 + HU141MRB U30R32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HN1616Y NB1 + HU143MRB U30R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

5 verified differences, most decision-relevant first. All are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HN1616Y NB1 + HU141MRB U30R32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30
LG HN1616Y NB1 + HU143MRB U30R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer sound declarations and measurement methods

In Visual facts
LG HN1616Y NB1 + HU141MRB U30220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39
LG HN1616Y NB1 + HU143MRB U30380-415, 3, 50; White / RAL 9002; 44 dB(A); 63 / 61
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 220-240, 1, 50; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): White / RAL 9002; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 39. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 380-415, 3, 50; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): White / RAL 9002; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 63 / 61. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

55 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HN1616Y NB1 + HU141MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1616Y NB1 + HU141MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HN1616Y NB1 + HU143MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1616Y NB1 + HU143MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
60 of 60 specifications Sources in each row
Source-backed specifications for LG HN1616Y NB1 + HU141MRB U30 and LG HN1616Y NB1 + HU143MRB U30
SpecificationLG HN1616Y NB1 + HU141MRB U30LG HN1616Y NB1 + HU143MRB U30
Manufacturer heating capacities at separate operating points
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — Heating capacity (kW): 11.50; NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — Heating capacity (kW): 11.50; NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): -25 ~ 35; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15 ~ 65. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): -25 ~ 35; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15 ~ 65. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7)-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7)
Manufacturer efficiency declarations and source methods
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — COP: 2.85; NOMINAL CAPACITY AND COP (A-7/W+55) — COP: 2.60; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.63; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.89; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 4.30; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 5 ~ 48; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 5 ~ 27; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 180 / 136; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.57 / 3.47; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 120; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — COP: 2.85; NOMINAL CAPACITY AND COP (A-7/W+55) — COP: 2.60; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.63; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.89; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 4.30; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 5 ~ 48; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 5 ~ 27; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 180 / 136; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.57 / 3.47; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 120; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
COP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+COP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+
NOMINAL CAPACITY AND COP (A-7/W+35) — Heating capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
11.5011.50
NOMINAL CAPACITY AND COP (A-7/W+35) — COP
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
2.852.85
NOMINAL CAPACITY AND COP (A-7/W+55) — COP
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
2.602.60
NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
14.0014.00
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
3.633.63
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
12.0012.00
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
4.894.89
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
14.0014.00
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
4.304.30
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
14.0014.00
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
-25 ~ 35-25 ~ 35
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
5 ~ 485 ~ 48
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
15 ~ 6515 ~ 65
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
5 ~ 275 ~ 27
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
180 / 136180 / 136
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
4.57 / 3.474.57 / 3.47
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
A+++/A++A+++/A++
WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
120120
WATER HEATING EFFICIENCY DATA — COPDHW, average climate
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
2.742.74
WATER HEATING EFFICIENCY DATA — Declared load profile, average climate
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
LL
WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
A+A+
Manufacturer refrigerant type
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: Male PT 1". Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: Male PT 1". Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
REFRIGERANT — GWP
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Female G1"Female G1"
REFRIGERANT — Precharged amount (g)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Female G1"Female G1"
REFRIGERANT — Type
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
Manufacturer electrical supply requirements
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
220-240, 1, 50220-240, 1, 50
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
220-240, 1, 50220-240, 1, 50
Exact manufacturer unit purposeDifferent
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
R32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Manufacturer dimensions and configuration basis
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm))490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm))
DIMENSIONS — Indoor unit (W × H × D) (mm)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
490 × 850 × 315490 × 850 × 315
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
950 x 1,380 x 330950 x 1,380 x 330
EXTERIOR — Indoor unit (Color / RAL code)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Noble white / RAL 9016Noble white / RAL 9016
EXTERIOR — Outdoor unit (Color / RAL code)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Warm gray / RAL 7044Warm gray / RAL 7044
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Female G3/4"Female G3/4"
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
62 / 6062 / 60
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
4343
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Female G3/4"Female G3/4"
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
3535
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
40 / 3840 / 38
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
950 × 1,380 × 330950 × 1,380 × 330
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for DHW (inch)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
91.791.7
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for DHW (inch)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
130.0130.0
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
601 × 1,812 × 685601 × 1,812 × 685
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Warm gray / RAL 7044Warm gray / RAL 7044
WEIGHT — Indoor unit (Empty) (kg)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
40.540.5
WEIGHT — Outdoor unit (Empty) (kg)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
84.884.8
Manufacturer operating ranges and conditions
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 2,100; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): Male PT 1"; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 675; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): R32; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 2,100; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): Male PT 1"; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 675; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): R32; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
2,100; Male PT 1"; 675; R32; 15 ~ 802,100; Male PT 1"; 675; R32; 15 ~ 80
Manufacturer sound declarations and measurement methodsDifferent
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 220-240, 1, 50; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): White / RAL 9002; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 39. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 380-415, 3, 50; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): White / RAL 9002; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 63 / 61. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39380-415, 3, 50; White / RAL 9002; 44 dB(A); 63 / 61
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
2,1002,100
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
675675
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
R32R32
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
15 ~ 8015 ~ 80
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))Different
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
220-240, 1, 50380-415, 3, 50
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
White / RAL 9002White / RAL 9002
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))Different
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
3644
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))Different
Sources
LG HN1616Y NB1 + HU141MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU141MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU143MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
41 / 3963 / 61
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R410A Split Hydro Box, 1Ø, 12kW HN1616M NK5 + HU121MA U33

LG HN1616M NK5 + HU121MA U33

Exact manufacturer unit purpose
R410A Split Hydro Box, 1Ø, 12kW HN1616M NK5 + HU121MA U33
Manufacturer heating capacities at separate operating points
11.00 kW (A+2/W+35); 12.00 kW (A+7/W+35); 11.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
10.40 kW (A+35/W+18); 7.94 kW (A+35/W+7)
Prices & product profile
Front view of R32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30

LG HN1600MC NK1 + HU121MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30
Manufacturer heating capacities at separate operating points
12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Prices & product profile
Front view of R410A Split Hydro Box, 1Ø, 14kW HN1616M NK5 + HU141MA U33

LG HN1616M NK5 + HU141MA U33

Exact manufacturer unit purpose
R410A Split Hydro Box, 1Ø, 14kW HN1616M NK5 + HU141MA U33
Manufacturer heating capacities at separate operating points
11.50 kW (A+7/W+55); 14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35)
Manufacturer cooling capacities at separate operating points
12.00 kW (A+35/W+18); 8.50 kW (A+35/W+7)
Prices & product profile
Front view of R32 Hydrosplit Hydro Box, 1Ø, 14kW HN1600MC NK1 + HU141MRB U30

LG HN1600MC NK1 + HU141MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 14kW HN1600MC NK1 + HU141MRB U30
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile

Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.