Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HN1600MC NK1 + HU163MRB U30 vs LG HN1616Y NB1 + HU163MRB U30

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HN1600MC NK1 + HU163MRB U30

UK manufacturer configuration · HN1600MC NK1 + HU163MRB U30

Front view of R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30
Exact model & source notes

LG HN1600MC NK1 + HU163MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
DIMENSIONS — Indoor unit (W × H × D) (mm)490 × 850 × 315601 × 1,812 × 685
EXTERIOR — Indoor unit (Color / RAL code)Noble white / RAL 9016White / RAL 9002
NOMINAL CAPACITY AND COP (A+7/W+55) — COP2.802.5
3 of 14 verified differences, in the order listed below. Not a rating.
See the 14 verified differences
THE CONTENDER

LG HN1616Y NB1 + HU163MRB U30

UK manufacturer configuration · HN1616Y NB1 + HU163MRB U30

Front view of R32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30
Exact model & source notes

LG HN1616Y NB1 + HU163MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HN1600MC NK1 + HU163MRB U30 UK & US retailers

UK & US price history: no verified listing yet

HN1616Y NB1 + HU163MRB U30 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE7 topics
SELECTED TOPIC
01 / 07

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HN1616Y NB1 + HU163MRB U30R32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

14 verified differences, most decision-relevant first. 7 are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30
LG HN1616Y NB1 + HU163MRB U30R32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer heating capacities at separate operating points

In Visual facts
LG HN1600MC NK1 + HU163MRB U3016.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
LG HN1616Y NB1 + HU163MRB U3016 kW (A-7/W+55); 13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 16; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer efficiency declarations and source methods

In Visual facts
LG HN1600MC NK1 + HU163MRB U30Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)
LG HN1616Y NB1 + HU163MRB U30COP 2.5 (A-7/W+55); COP 3.60 (A+2/W+35); COP 4.80 (A+7/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+55) — COP: 2.5; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 120; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer sound declarations and measurement methods

In Visual facts
LG HN1600MC NK1 + HU163MRB U3063 / 60; 44 dB(A); 41 / 38; 36 dB(A)
LG HN1616Y NB1 + HU163MRB U3043 dB(A); 63 / 60; 35 dB(A); 41 / 38
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 43; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 35; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer dimensions and configuration basis

In Visual facts
LG HN1600MC NK1 + HU163MRB U30950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))
LG HN1616Y NB1 + HU163MRB U30601 × 1,812 × 685 (Indoor unit (W × H × D) (mm)); 950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

A size or weight trade-off; it does not establish the better product.

Show 8 more verified differences
Missing or non-comparable evidence (8)

NOMINAL CAPACITY AND COP (A+7/W+55) — COP

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U302.80
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U3012.00
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for DHW (inch)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U30Female G3/4"
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U30Female G3/4"
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — COPDHW, average climate

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U302.74
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — Declared load profile, average climate

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U30L
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U30A+
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1616Y NB1 + HU163MRB U30120
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

31 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HN1600MC NK1 + HU163MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1600MC NK1 + HU163MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HN1616Y NB1 + HU163MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1616Y NB1 + HU163MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
53 of 53 specifications Sources in each row
Source-backed specifications for LG HN1600MC NK1 + HU163MRB U30 and LG HN1616Y NB1 + HU163MRB U30
SpecificationLG HN1600MC NK1 + HU163MRB U30LG HN1616Y NB1 + HU163MRB U30
Manufacturer heating capacities at separate operating pointsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 16; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)16 kW (A-7/W+55); 13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Manufacturer efficiency declarations and source methodsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+55) — COP: 2.5; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 120; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)COP 2.5 (A-7/W+55); COP 3.60 (A+2/W+35); COP 4.80 (A+7/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
179 / 135179 / 135
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
A+++/A++A+++/A++
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
4.55 / 3.454.55 / 3.45
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
4.804.80
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
13.8013.80
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
3.603.60
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
12.0016
NOMINAL CAPACITY AND COP (A+7/W+55) — COPDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
2.802.5
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
4.004.00
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
2.502.50
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not provided2.80
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not provided12.00
WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not provided120
WATER HEATING EFFICIENCY DATA — COPDHW, average climate
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not provided2.74
WATER HEATING EFFICIENCY DATA — Declared load profile, average climate
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not providedL
WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not providedA+
Manufacturer refrigerant type
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
R32R32
REFRIGERANT — Type
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
R32R32
REFRIGERANT — GWP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
675675
REFRIGERANT — Precharged amount (g)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
2,1002,100
Manufacturer electrical supply requirements
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
380-415, 3, 50380-415, 3, 50
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
380-415, 3, 50380-415, 3, 50
Exact manufacturer unit purposeDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30R32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30
Manufacturer dimensions and configuration basisDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))601 × 1,812 × 685 (Indoor unit (W × H × D) (mm)); 950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm))
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Male PT 1"Female G1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Male PT 1"Female G1"
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
950 × 1,380 × 330950 × 1,380 × 330
DIMENSIONS — Indoor unit (W × H × D) (mm)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
490 × 850 × 315601 × 1,812 × 685
WEIGHT — Outdoor unit (Empty) (kg)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
91.791.7
WEIGHT — Indoor unit (Empty) (kg)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
30.5130.0
EXTERIOR — Outdoor unit (Color / RAL code)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Warm gray / RAL 7044Warm gray / RAL 7044
EXTERIOR — Indoor unit (Color / RAL code)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Noble white / RAL 9016White / RAL 9002
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for DHW (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not providedFemale G3/4"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Not providedFemale G3/4"
Manufacturer operating ranges and conditions
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
5 ~ 48; -25 ~ 35; 15 ~ 65; 5 ~ 27; 15 ~ 805 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 35
Manufacturer sound declarations and measurement methodsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 43; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 35; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
63 / 60; 44 dB(A); 41 / 38; 36 dB(A)43 dB(A); 63 / 60; 35 dB(A); 41 / 38
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
-25 ~ 35-25 ~ 35
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
15 ~ 6515 ~ 65
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
15 ~ 8015 ~ 80
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
63 / 6063 / 60
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
4443
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
41 / 3841 / 38
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1616Y NB1 + HU163MRB U30

Manufacturer specification

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
3635
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Monobloc S, 3Ø, 16kW HM163MR U34

LG HM163MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 3Ø, 16kW HM163MR U34
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+7); 16.00 kW (A+35/W+18)
Prices & product profile
Front view of R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30

LG HN1600MC NK1 + HU161MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30

LG HN1616Y NB1 + HU161MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 1Ø, 16kW HM161MR U34

LG HM161MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 16kW HM161MR U34
Manufacturer heating capacities at separate operating points
13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile

Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.