Skip to specifications
versus.deals
Menu
Browse versus.deals
HEAT PUMPS

LG HN1616Y NB1 + HU161MRB U30

UK configuration

Exact manufacturer unit purpose
R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)

LG HN1616Y NB1 + HU161MRB U30 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG HN1616Y NB1 + HU161MRB U30 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG HM161MR U34

Specifications checked 19 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked heat pumps by key specifications, with what differs from the LG HN1616Y NB1 + HU161MRB U30. The first matches the Compare button above.

Front view of R32 Monobloc S, 1Ø, 16kW HM161MR U34LG HM161MR U34UK manufacturer configuration · HM161MR U34
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 16kW HM161MR U34This one: R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Manufacturer efficiency declarations and source methods
COP 3.60 (A+2/W+35); COP 4.70 (A+7/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 3.10 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 178 / 135; SCOP (35℃ / 55℃) 4.53 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++This one: Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)
Front view of R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30LG HN1600MC NK1 + HU161MRB U30UK manufacturer configuration · HN1600MC NK1 + HU161MRB U30
Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30This one: R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Manufacturer efficiency declarations and source methods
Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)This one: Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)
LG Air to Water Heat Pumps  HM161MRS UB40, front view of a black outdoor unit featuring a grey wavy grille.LG HM161MRSUK manufacturer configuration · HM161MRS
Exact manufacturer unit purpose
R32 Monobloc S II, 1Ø, 16kWThis one: R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)This one: 16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
The useful part.

Key strengths

The official LG UK page identifies manufacturer model HN1616Y NB1 + HU161MRB U30.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · HN1616Y NB1 + HU161MRB U30

42 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 9 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

18 items
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer efficiency declarations and source methods
Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 120; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
A+++/A++Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
179 / 135Source
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
4.55 / 3.45Source
WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate
A+Source
WATER HEATING EFFICIENCY DATA — Declared load profile, average climate
LSource
WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate
120Source
WATER HEATING EFFICIENCY DATA — COPDHW, average climate
2.74Source
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
16.00Source
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
4.80Source
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
13.80Source
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
3.60Source
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
12.00Source
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
2.80Source
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
4.00Source
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
2.50Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
16.00Source
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
16.00Source

Refrigerant & circuit

3 items
Manufacturer refrigerant type
R32

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
REFRIGERANT — GWP
675Source
REFRIGERANT — Precharged amount (g)
2,100Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

REFRIGERANT — Type
R32Source

Electrical supply & consumption

1 item
Manufacturer electrical supply requirements
220-240, 1, 50

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
220-240, 1, 50Source

Installation, dimensions & airflow

10 items
Exact manufacturer unit purpose
R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Male PT 1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)
Female G1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for DHW (inch)
Female G3/4"Source
DIMENSIONS — Outdoor unit (W × H × D) (mm)
950 × 1,380 × 330Source
DIMENSIONS — Indoor unit (W × H × D) (mm)
601 × 1,812 × 685Source
WEIGHT — Outdoor unit (Empty) (kg)
91.7Source
WEIGHT — Indoor unit (Empty) (kg)
130.0Source
EXTERIOR — Outdoor unit (Color / RAL code)
Warm gray / RAL 7044Source
EXTERIOR — Indoor unit (Color / RAL code)
White / RAL 9002Source
Manufacturer wording (4)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 601 × 1,812 × 685 (Indoor unit (W × H × D) (mm))

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

Source
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Male PT 1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)
Female G1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)
Female G3/4"Source

Operating conditions & sound

10 items
Manufacturer sound declarations and measurement methods
63 / 60; 43 dB(A); 41 / 38; 35 dB(A)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 43; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
-25 ~ 35Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
5 ~ 48Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
15 ~ 65Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
5 ~ 27Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
15 ~ 80Source
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
63 / 60Source
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))
43Source
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
41 / 38Source
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))
35Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer operating ranges and conditions
-25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Similar products.

Compare with another heat pumps product

More of the nearest checked heat pumps by key specifications, for a side-by-side comparison.