Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HN1600MC NK1 + HU163MRB U30 vs LG HN1600MC NK1 + HU161MRB U30

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HN1600MC NK1 + HU163MRB U30

UK manufacturer configuration · HN1600MC NK1 + HU163MRB U30

Front view of R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30
Exact model & source notes

LG HN1600MC NK1 + HU163MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
Manufacturer electrical supply requirements380-415, 3, 50220-240, 1, 50
1 of 3 verified differences, in the order listed below. Not a rating.
See the 3 verified differences
THE CONTENDER

LG HN1600MC NK1 + HU161MRB U30

UK manufacturer configuration · HN1600MC NK1 + HU161MRB U30

Front view of R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30
Exact model & source notes

LG HN1600MC NK1 + HU161MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HU163MRB U30 UK & US retailers

UK & US price history: no verified listing yet

HU161MRB U30 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE3 topics
SELECTED TOPIC
01 / 03

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HN1600MC NK1 + HU161MRB U30R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

3 verified differences, most decision-relevant first. All are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30
LG HN1600MC NK1 + HU161MRB U30R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer electrical supply requirements

In Visual facts
LG HN1600MC NK1 + HU163MRB U30380-415, 3, 50
LG HN1600MC NK1 + HU161MRB U30220-240, 1, 50
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

42 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HN1600MC NK1 + HU163MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1600MC NK1 + HU163MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HN1600MC NK1 + HU161MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1600MC NK1 + HU161MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
45 of 45 specifications Sources in each row
Source-backed specifications for LG HN1600MC NK1 + HU163MRB U30 and LG HN1600MC NK1 + HU161MRB U30
SpecificationLG HN1600MC NK1 + HU163MRB U30LG HN1600MC NK1 + HU161MRB U30
Manufacturer heating capacities at separate operating points
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Manufacturer efficiency declarations and source methods
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
179 / 135179 / 135
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
A+++/A++A+++/A++
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
4.55 / 3.454.55 / 3.45
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
4.804.80
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
13.8013.80
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
3.603.60
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
12.0012.00
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
2.802.80
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
4.004.00
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
2.502.50
Manufacturer refrigerant type
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
R32R32
REFRIGERANT — Type
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
R32R32
REFRIGERANT — GWP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
675675
REFRIGERANT — Precharged amount (g)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
2,1002,100
Manufacturer electrical supply requirementsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
380-415, 3, 50220-240, 1, 50
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
380-415, 3, 50220-240, 1, 50
Exact manufacturer unit purposeDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30
Manufacturer dimensions and configuration basis
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Male PT 1"Male PT 1"
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
950 × 1,380 × 330950 × 1,380 × 330
DIMENSIONS — Indoor unit (W × H × D) (mm)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
490 × 850 × 315490 × 850 × 315
WEIGHT — Outdoor unit (Empty) (kg)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
91.791.7
WEIGHT — Indoor unit (Empty) (kg)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
30.530.5
EXTERIOR — Outdoor unit (Color / RAL code)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Warm gray / RAL 7044Warm gray / RAL 7044
EXTERIOR — Indoor unit (Color / RAL code)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
Noble white / RAL 9016Noble white / RAL 9016
Manufacturer operating ranges and conditions
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
5 ~ 48; -25 ~ 35; 15 ~ 65; 5 ~ 27; 15 ~ 80-25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80
Manufacturer sound declarations and measurement methods
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
63 / 60; 44 dB(A); 41 / 38; 36 dB(A)63 / 60; 44 dB(A); 41 / 38; 36 dB(A)
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
-25 ~ 35-25 ~ 35
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
15 ~ 6515 ~ 65
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
15 ~ 8015 ~ 80
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
63 / 6063 / 60
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
4444
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
41 / 3841 / 38
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1600MC NK1 + HU161MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU161MRB U30 manufacturer specifications
3636
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Monobloc S, 1Ø, 16kW HM161MR U34

LG HM161MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 16kW HM161MR U34
Manufacturer heating capacities at separate operating points
13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 3Ø, 16kW HM163MR U34

LG HM163MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 3Ø, 16kW HM163MR U34
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+7); 16.00 kW (A+35/W+18)
Prices & product profile
Front view of R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30

LG HN1616Y NB1 + HU161MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile
LG Air to Water Heat Pumps  HM161MRS UB40, front view of a black outdoor unit featuring a grey wavy grille.

LG HM161MRS

Exact manufacturer unit purpose
R32 Monobloc S II, 1Ø, 16kW
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)
Prices & product profile

Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.