Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HM141MRS vs LG HM143MRS UB40

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HM141MRS

UK manufacturer configuration · HM141MRS

LG Air to Water Heat Pumps  HM141MRS UB40, front view of a black outdoor unit featuring a grey wavy grille.
Exact model & source notes

LG HM141MRS in the exact manufacturer-listed UK configuration.

Specifications checked 20 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
Manufacturer electrical supply requirements220 ~ 240, 1, 50380 ~ 415, 3, 50
1 of 3 verified differences, in the order listed below. Not a rating.
See the 3 verified differences
THE CONTENDER

LG HM143MRS UB40

UK manufacturer configuration · HM143MRS UB40

Front view of R32 Monobloc S II, 3Ø, 14kW HM143MRS UB40
Exact model & source notes

LG HM143MRS UB40 in the exact manufacturer-listed UK configuration.

Specifications checked 20 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HM141MRS UK & US retailers

UK & US price history: no verified listing yet

HM143MRS UB40 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE3 topics
SELECTED TOPIC
01 / 03

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HM141MRSR32 Monobloc S II, 1Ø, 14kW

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HM143MRS UB40R32 Monobloc S II, 3Ø, 14kW

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

3 verified differences, most decision-relevant first. All are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HM141MRSR32 Monobloc S II, 1Ø, 14kW
LG HM143MRS UB40R32 Monobloc S II, 3Ø, 14kW
Sources
LG HM141MRS

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM143MRS UB40 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer electrical supply requirements

In Visual facts
LG HM141MRS220 ~ 240, 1, 50
LG HM143MRS UB40380 ~ 415, 3, 50
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 220 ~ 240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 380 ~ 415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications

Check the exact configuration and source conditions for your use.

35 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HM141MRS

What it brings

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HM143MRS UB40

What it brings

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
38 of 38 specifications Sources in each row
Source-backed specifications for LG HM141MRS and LG HM143MRS UB40
SpecificationLG HM141MRSLG HM143MRS UB40
Manufacturer heating capacities at separate operating points
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 14.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 14.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Manufacturer efficiency declarations and source methods
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.62 / 3.46; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.55; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.85; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.70; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.10. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.55; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.85; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.70; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.10; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.62 / 3.46; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
SCOP (35℃ / 55℃) 4.62 / 3.46; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; COP 4.80 (A+7/W+35); COP 3.55 (A+2/W+35); COP 2.85 (A+7/W+55); EER 4.70 (A+35/W+18); EER 3.10 (A+35/W+7)COP 3.55 (A+2/W+35); COP 4.80 (A+7/W+35); COP 2.85 (A+7/W+55); EER 4.70 (A+35/W+18); EER 3.10 (A+35/W+7); SCOP (35℃ / 55℃) 4.62 / 3.46; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
4.62 / 3.464.62 / 3.46
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
A+++/A++A+++/A++
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
4.804.80
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
14.0014.00
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
3.553.55
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
12.0012.00
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
2.852.85
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
11.5011.50
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
14.0014.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
4.704.70
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
14.0014.00
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
3.103.10
Manufacturer refrigerant type
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
R32R32
REFRIGERANT — Type
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
R32R32
REFRIGERANT — GWP
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
675675
REFRIGERANT — Precharged amount (g)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
1,6001,600
Manufacturer electrical supply requirementsDifferent
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 220 ~ 240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 380 ~ 415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
220 ~ 240, 1, 50380 ~ 415, 3, 50
POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz)Different
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
220 ~ 240, 1, 50380 ~ 415, 3, 50
Exact manufacturer unit purposeDifferent
Sources
LG HM141MRS

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM143MRS UB40 manufacturer specifications
R32 Monobloc S II, 1Ø, 14kWR32 Monobloc S II, 3Ø, 14kW
Manufacturer dimensions and configuration basis
Sources
LG HM141MRS

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HM143MRS UB40 manufacturer specifications
1,320 x 1,019 x 520 mm1,320 x 1,019 x 520 mm
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
Male PT 1"Male PT 1"
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
Male PT 1"Male PT 1"
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
1,320 x 1,019 x 5201,320 x 1,019 x 520
WEIGHT — Outdoor unit (Empty) (kg)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
117.0117.0
EXTERIOR — Color of outdoor unit chassis (Color / RAL code)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
Dawn gray / RAL 7037Dawn gray / RAL 7037
EXTERIOR — Color of outdoor unit front grille (Color / RAL code)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
Dark dawn gray / RAL 7012Dark dawn gray / RAL 7012
Manufacturer operating ranges and conditions
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
5 ~ 48; -25 ~ 35; 5 ~ 27; 15 ~ 80; 15 ~ 655 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 35
Manufacturer sound declarations and measurement methods
Sources
LG HM141MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MRS UB40 manufacturer specifications
61 / 57; 39 / 3561 / 57; 39 / 35
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
-25 ~ 35-25 ~ 35
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
15 ~ 8015 ~ 80
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
15 ~ 6515 ~ 65
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
61 / 5761 / 57
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM141MRS

Manufacturer specification

LG UK — HM141MRS manufacturer specifications
LG HM143MRS UB40

Manufacturer specification

LG UK — HM143MRS UB40 manufacturer specifications
39 / 3539 / 35
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Monobloc S, 1Ø, 14kW HM141MR U34

LG HM141MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 14kW HM141MR U34
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 3Ø, 14kW HM143MR U34

LG HM143MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 3Ø, 14kW HM143MR U34
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Hydrosplit Hydro Box, 1Ø, 14kW HN1600MC NK1 + HU141MRB U30

LG HN1600MC NK1 + HU141MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 14kW HN1600MC NK1 + HU141MRB U30
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Hydrosplit Hydro Box, 3Ø, 14kW HN1600MC NK1 + HU143MRB U30

LG HN1600MC NK1 + HU143MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 3Ø, 14kW HN1600MC NK1 + HU143MRB U30
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile

Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.