Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
Exact configuration: UK manufacturer configuration · HM143MR U34
31 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 7 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.
Heating, cooling & efficiency
14 items
Manufacturer heating capacities at separate operating points
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 14.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.30; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.30; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.63; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.85; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.62 / 3.46; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 182 / 135. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.
The same facts in the manufacturer’s combined or original wording, each with its source.
Manufacturer operating ranges and conditions
5 ~ 48; -25 ~ 35; 5 ~ 27; 15 ~ 65; 15 ~ 80
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer sound declarations and measurement methods
61 / 57; 53 / 49; 39 / 35
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 53 / 49; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.