Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HM123MRS UB40 vs LG HM143MR U34

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HM123MRS UB40

UK manufacturer configuration · HM123MRS UB40

Front view of R32 Monobloc S II, 3Ø, 12kW HM123MRS UB40
Exact model & source notes

LG HM123MRS UB40 in the exact manufacturer-listed UK configuration.

Specifications checked 20 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
Manufacturer sound declarations and measurement methods60 / 56; 38 / 3461 / 57; 53 / 49; 39 / 35
NOMINAL CAPACITY AND COP (A+2/W+35) — COP3.603.63
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)11.0012.00
3 of 16 verified differences, in the order listed below. Not a rating.
See the 16 verified differences
THE CONTENDER

LG HM143MR U34

UK manufacturer configuration · HM143MR U34

Front view of R32 Monobloc S, 3Ø, 14kW HM143MR U34
Exact model & source notes

LG HM143MR U34 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HM123MRS UB40 UK & US retailers

UK & US price history: no verified listing yet

HM143MR U34 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE7 topics
SELECTED TOPIC
01 / 07

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HM123MRS UB40R32 Monobloc S II, 3Ø, 12kW

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HM143MR U34R32 Monobloc S, 3Ø, 14kW HM143MR U34

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

16 verified differences, most decision-relevant first. 7 are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HM123MRS UB40R32 Monobloc S II, 3Ø, 12kW
LG HM143MR U34R32 Monobloc S, 3Ø, 14kW HM143MR U34
Sources
LG HM123MRS UB40

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM143MR U34 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer heating capacities at separate operating points

In Visual facts
LG HM123MRS UB4011.00 kW (A+2/W+35); 12.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
LG HM143MR U3414.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer cooling capacities at separate operating points

In Visual facts
LG HM123MRS UB4012.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
LG HM143MR U3414.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 12.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 14.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer efficiency declarations and source methods

In Visual facts
LG HM123MRS UB40COP 3.60 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.90 (A+7/W+55); EER 4.80 (A+35/W+18); EER 3.20 (A+35/W+7); SCOP (35℃ / 55℃) 4.67 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++
LG HM143MR U34EER 4.30 (A+35/W+18); EER 3.30 (A+35/W+7); COP 4.80 (A+7/W+35); COP 3.63 (A+2/W+35); COP 2.85 (A+7/W+55); SCOP (35℃ / 55℃) 4.62 / 3.46; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 182 / 135
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.90; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.90; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.80; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.20; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.67 / 3.47; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.30; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.30; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.63; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.85; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.62 / 3.46; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 182 / 135. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer sound declarations and measurement methods

In Visual facts
LG HM123MRS UB4060 / 56; 38 / 34
LG HM143MR U3461 / 57; 53 / 49; 39 / 35
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 60 / 56; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 38 / 34. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 53 / 49; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications

Check the exact configuration and source conditions for your use.

Show 10 more verified differences
Missing or non-comparable evidence (23)

Manufacturer dimensions and configuration basis

LG HM123MRS UB401,320 x 1,019 x 520 mm
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · Manufacturer specification · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

DIMENSIONS — Outdoor unit (W × H × D) (mm)

LG HM123MRS UB401,320 x 1,019 x 520
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — Color

LG HM123MRS UB40Not verified
LG HM143MR U34Warm gray
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — Color of outdoor unit chassis (Color / RAL code)

LG HM123MRS UB40Dawn gray / RAL 7037
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — Color of outdoor unit front grille (Color / RAL code)

LG HM123MRS UB40Dark dawn gray / RAL 7012
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — RAL code

LG HM123MRS UB40Not verified
LG HM143MR U34RAL 7044
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER) — Inlet diameter (inch)

LG HM123MRS UB40Not verified
LG HM143MR U34Male PT 1"
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)

LG HM123MRS UB40Male PT 1"
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)

LG HM123MRS UB40Male PT 1"
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER) — Outlet diameter (inch)

LG HM123MRS UB40Not verified
LG HM143MR U34Male PT 1"
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz)

LG HM123MRS UB40380 ~ 415, 3, 50
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)

LG HM123MRS UB40Not verified
LG HM143MR U34380-415, 3, 50
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))

LG HM123MRS UB4060 / 56
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND POWER LEVEL — Rated / low noise mode (dB(A))

LG HM123MRS UB40Not verified
LG HM143MR U3461 / 57
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A))

LG HM123MRS UB40Not verified
LG HM143MR U3453 / 49
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A))

LG HM123MRS UB40Not verified
LG HM143MR U3439 / 35
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))

LG HM123MRS UB4038 / 34
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WEIGHT — Outdoor unit (Empty) (kg)

LG HM123MRS UB40117.0
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)

LG HM123MRS UB404.67 / 3.47
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)

LG HM123MRS UB40A+++/A++
LG HM143MR U34Not verified
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃)

LG HM123MRS UB40Not verified
LG HM143MR U344.62 / 3.46
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃)

LG HM123MRS UB40Not verified
LG HM143MR U34A+++/A++
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃)

LG HM123MRS UB40Not verified
LG HM143MR U34182 / 135
Sources
LG HM123MRS UB40

No source recorded for this side.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

10 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HM123MRS UB40

What it brings

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HM143MR U34

What it brings

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
49 of 49 specifications Sources in each row
Source-backed specifications for LG HM123MRS UB40 and LG HM143MR U34
SpecificationLG HM123MRS UB40LG HM143MR U34
Manufacturer heating capacities at separate operating pointsDifferent
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
11.00 kW (A+2/W+35); 12.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating pointsDifferent
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 12.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 14.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Manufacturer efficiency declarations and source methodsDifferent
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.90; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.90; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.80; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.20; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.67 / 3.47; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.30; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.30; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.63; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.85; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.62 / 3.46; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 182 / 135. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
COP 3.60 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.90 (A+7/W+55); EER 4.80 (A+35/W+18); EER 3.20 (A+35/W+7); SCOP (35℃ / 55℃) 4.67 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++EER 4.30 (A+35/W+18); EER 3.30 (A+35/W+7); COP 4.80 (A+7/W+35); COP 3.63 (A+2/W+35); COP 2.85 (A+7/W+55); SCOP (35℃ / 55℃) 4.62 / 3.46; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 182 / 135
NOMINAL CAPACITY AND COP (A+2/W+35) — COPDifferent
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
3.603.63
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)Different
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
11.0012.00
NOMINAL CAPACITY AND COP (A+7/W+35) — COPDifferent
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
4.904.80
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)Different
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
12.0014.00
NOMINAL CAPACITY AND COP (A+7/W+55) — COPDifferent
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
2.902.85
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)Different
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
12.0011.50
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)Different
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
12.0014.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EERDifferent
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
4.804.30
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)Different
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
12.0014.00
NOMINAL CAPACITY AND EER (A+35/W+7) — EERDifferent
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
3.203.30
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

4.67 / 3.47Not provided
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

A+++/A++Not provided
SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃)
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not provided4.62 / 3.46
SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not providedA+++/A++
SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not provided182 / 135
Manufacturer refrigerant type
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
R32R32
REFRIGERANT — Type
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
R32R32
REFRIGERANT — GWP
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
675675
REFRIGERANT — Precharged amount (g)Different
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
1,6002,000
Manufacturer electrical supply requirements
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 380 ~ 415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
380 ~ 415, 3, 50380-415, 3, 50
POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

380 ~ 415, 3, 50Not provided
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not provided380-415, 3, 50
Exact manufacturer unit purposeDifferent
Sources
LG HM123MRS UB40

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM143MR U34 manufacturer specifications
R32 Monobloc S II, 3Ø, 12kWR32 Monobloc S, 3Ø, 14kW HM143MR U34
Manufacturer dimensions and configuration basis
Sources
LG HM123MRS UB40

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · Manufacturer specification · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.

LG UK — HM143MR U34 manufacturer specifications
1,320 x 1,019 x 520 mmNot listed by the manufacturer
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

1,320 x 1,019 x 520Not provided
WEIGHT — Outdoor unit (Empty) (kg)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

117.0Not provided
EXTERIOR — Color of outdoor unit chassis (Color / RAL code)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

Dawn gray / RAL 7037Not provided
EXTERIOR — Color of outdoor unit front grille (Color / RAL code)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

Dark dawn gray / RAL 7012Not provided
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

Male PT 1"Not provided
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

Male PT 1"Not provided
PIPING CONNECTIONS (WATER) — Inlet diameter (inch)
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not providedMale PT 1"
PIPING CONNECTIONS (WATER) — Outlet diameter (inch)
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not providedMale PT 1"
EXTERIOR — Color
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not providedWarm gray
EXTERIOR — RAL code
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not providedRAL 7044
Manufacturer operating ranges and conditions
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
5 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 355 ~ 48; -25 ~ 35; 5 ~ 27; 15 ~ 65; 15 ~ 80
Manufacturer sound declarations and measurement methodsDifferent
Sources
LG HM123MRS UB40

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 60 / 56; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 38 / 34. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 53 / 49; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM143MR U34 manufacturer specifications
60 / 56; 38 / 3461 / 57; 53 / 49; 39 / 35
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

60 / 56Not provided
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
15 ~ 8015 ~ 80
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
15 ~ 6515 ~ 65
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
-25 ~ 35-25 ~ 35
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM123MRS UB40

Manufacturer specification

LG UK — HM123MRS UB40 manufacturer specifications
LG HM143MR U34

No source recorded.

38 / 34Not provided
SOUND POWER LEVEL — Rated / low noise mode (dB(A))
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not provided61 / 57
SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not provided53 / 49
SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM123MRS UB40

No source recorded.

LG HM143MR U34

Manufacturer specification

LG UK — HM143MR U34 manufacturer specifications
Not provided39 / 35
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Monobloc S II, 3Ø, 14kW HM143MRS UB40

LG HM143MRS UB40

Exact manufacturer unit purpose
R32 Monobloc S II, 3Ø, 14kW
Manufacturer heating capacities at separate operating points
12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile
LG Air to Water Heat Pumps  HM121MRS UB40, front view of a black outdoor unit featuring a grey wavy grille.

LG HM121MRS

Exact manufacturer unit purpose
R32 Monobloc S II, 1Ø, 12kW
Manufacturer heating capacities at separate operating points
12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 1Ø, 14kW HM141MR U34

LG HM141MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 14kW HM141MR U34
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Hydrosplit Hydro Box, 3Ø, 14kW HN1600MC NK1 + HU143MRB U30

LG HN1600MC NK1 + HU143MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 3Ø, 14kW HN1600MC NK1 + HU143MRB U30
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile