Heat pumps · 1/5 in this check (kept in the link)

Share or save

The heat pump you are considering

LG HN1616Y NB1 + HU141MRB U30

UK manufacturer configuration · HN1616Y NB1 + HU141MRB U30
Manufacturer unit type and installation role
R32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30
Heating-capacity declarations and operating conditions
11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)
Manufacturer refrigerant declaration
Male PT 1"
Electrical supply requirements
220-240, 1, 50

Your shortlisted products

Your prioritiesCategory, search, shopping market, budget and must-haves

Alternatives to LG HN1616Y NB1 + HU141MRB U30

Select must-haves to check which products meet your requirements.

Closest to the LG HN1616Y NB1 + HU141MRB U30 by stated key specifications first. Closeness is not a ranking; each card lists what differs.

Front view of R32 Hydrosplit IWT, 1Ø, 12kW HN1616Y NB1 + HU121MRB U30
UK model

LG HN1616Y NB1 + HU121MRB U30

Compared with · LG HN1616Y NB1 + HU141MRB U30

  • Manufacturer unit type and installation roleR32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30 → R32 Hydrosplit IWT, 1Ø, 12kW HN1616Y NB1 + HU121MRB U30
  • Heating-capacity declarations and operating conditions11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55) → 12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
  • Manufacturer refrigerant declarationMale PT 1" → R32
  • Cooling-capacity declarations and operating conditions-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7) → 12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
  • Efficiency declarations, methods and operating conditionsCOP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+ → Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 181 / 137; SCOP (35℃ / 55℃) 4.60 / 3.50; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 5.04 (A+7/W+35); COP 3.65 (A+2/W+35); COP 2.90 (A+7/W+55); EER 4.75 (A+35/W+18); EER 2,70 (A+35/W+7)
3 more differences
  • Operating ranges and mode conditions2,100; Male PT 1"; 675; R32; 15 ~ 80 → -25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80
  • Sound declarations and measurement basis220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39 → 61 / 60; 43 dB(A); 39 / 38; 35 dB(A)
  • Dimensions and component basis490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm)) → 950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 601 × 1,812 × 685 (Indoor unit (W × H × D) (mm))

Same: Electrical supply requirements 220-240, 1, 50

Compare side by side
View details

Full comparison vs LG HN1616Y NB1 + HU123MRB U30

More details & evidence

Exact model: UK manufacturer configuration · HN1616Y NB1 + HU121MRB U30

Sources: 51 of 51 specifications cited.

Evidence · 100% source coverage

51/51 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeR32 Hydrosplit IWT, 1Ø, 12kW HN1616Y NB1 + HU121MRB U30
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specifications
Manufacturer heating capacities at separate operating points12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specifications
Manufacturer refrigerant typeR32
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specifications
Manufacturer electrical supply requirements220-240, 1, 50
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of R32 Hydrosplit IWT, 3Ø, 12kW HN1616Y NB1 + HU123MRB U30
UK model

LG HN1616Y NB1 + HU123MRB U30

Compared with · LG HN1616Y NB1 + HU141MRB U30

  • Manufacturer unit type and installation roleR32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30 → R32 Hydrosplit IWT, 3Ø, 12kW HN1616Y NB1 + HU123MRB U30
  • Heating-capacity declarations and operating conditions11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55) → 12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
  • Manufacturer refrigerant declarationMale PT 1" → R32
  • Electrical supply requirements220-240, 1, 50 → 380-415, 3, 50
  • Cooling-capacity declarations and operating conditions-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7) → 12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
4 more differences
  • Efficiency declarations, methods and operating conditionsCOP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+ → Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 181 / 137; SCOP (35℃ / 55℃) 4.60 / 3.50; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 5.04 (A+7/W+35); COP 3.65 (A+2/W+35); COP 2.90 (A+7/W+55); EER 4.75 (A+35/W+18); EER 2,70 (A+35/W+7)
  • Operating ranges and mode conditions2,100; Male PT 1"; 675; R32; 15 ~ 80 → -25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80
  • Sound declarations and measurement basis220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39 → 61 / 60; 43 dB(A); 39 / 38; 35 dB(A)
  • Dimensions and component basis490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm)) → 950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 601 × 1,812 × 685 (Indoor unit (W × H × D) (mm))
Compare side by side
View details

Full comparison vs LG HN1616Y NB1 + HU121MRB U30

More details & evidence

Exact model: UK manufacturer configuration · HN1616Y NB1 + HU123MRB U30

Sources: 51 of 51 specifications cited.

Evidence · 100% source coverage

51/51 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeR32 Hydrosplit IWT, 3Ø, 12kW HN1616Y NB1 + HU123MRB U30
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU123MRB U30 manufacturer specifications
Manufacturer heating capacities at separate operating points12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU123MRB U30 manufacturer specifications
Manufacturer refrigerant typeR32
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU123MRB U30 manufacturer specifications
Manufacturer electrical supply requirements380-415, 3, 50
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU123MRB U30 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
UK model

LG HN1616Y NB1 + HU143MRB U30

Compared with · LG HN1616Y NB1 + HU141MRB U30

  • Manufacturer unit type and installation roleR32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30 → R32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
  • Sound declarations and measurement basis220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39 → 380-415, 3, 50; White / RAL 9002; 44 dB(A); 63 / 61

Same: Heating-capacity declarations and operating conditions 11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55) · Manufacturer refrigerant declaration Male PT 1" · Electrical supply requirements 220-240, 1, 50

Compare side by side
View details

Full comparison vs LG HN1616Y NB1 + HU121MRB U30

More details & evidence

Exact model: UK manufacturer configuration · HN1616Y NB1 + HU143MRB U30

Sources: 60 of 60 specifications cited.

Evidence · 100% source coverage

60/60 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
60
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeR32 Hydrosplit IWT, 3Ø, 14kW HN1616Y NB1 + HU143MRB U30
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Manufacturer heating capacities at separate operating points11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55)
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+35) — Heating capacity (kW): 11.50; NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 14.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Manufacturer refrigerant typeMale PT 1"
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: Male PT 1". Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Manufacturer electrical supply requirements220-240, 1, 50
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU143MRB U30 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
UK model

LG HN1616Y NB1 + HU161MRB U30

Compared with · LG HN1616Y NB1 + HU141MRB U30

  • Manufacturer unit type and installation roleR32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30 → R32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
  • Heating-capacity declarations and operating conditions11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55) → 16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
  • Manufacturer refrigerant declarationMale PT 1" → R32
  • Cooling-capacity declarations and operating conditions-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7) → 16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
  • Efficiency declarations, methods and operating conditionsCOP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+ → Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)
3 more differences
  • Operating ranges and mode conditions2,100; Male PT 1"; 675; R32; 15 ~ 80 → -25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80
  • Sound declarations and measurement basis220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39 → 63 / 60; 43 dB(A); 41 / 38; 35 dB(A)
  • Dimensions and component basis490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm)) → 950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 601 × 1,812 × 685 (Indoor unit (W × H × D) (mm))

Same: Electrical supply requirements 220-240, 1, 50

Compare side by side
View details

Full comparison vs LG HN1616Y NB1 + HU121MRB U30

More details & evidence

Exact model: UK manufacturer configuration · HN1616Y NB1 + HU161MRB U30

Sources: 51 of 51 specifications cited.

Evidence · 100% source coverage

51/51 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeR32 Hydrosplit IWT, 1Ø, 16kW HN1616Y NB1 + HU161MRB U30
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU161MRB U30 manufacturer specifications
Manufacturer heating capacities at separate operating points16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU161MRB U30 manufacturer specifications
Manufacturer refrigerant typeR32
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU161MRB U30 manufacturer specifications
Manufacturer electrical supply requirements220-240, 1, 50
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU161MRB U30 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of R32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30
UK model

LG HN1616Y NB1 + HU163MRB U30

Compared with · LG HN1616Y NB1 + HU141MRB U30

  • Manufacturer unit type and installation roleR32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30 → R32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30
  • Heating-capacity declarations and operating conditions11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55) → 16 kW (A-7/W+55); 13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
  • Manufacturer refrigerant declarationMale PT 1" → R32
  • Electrical supply requirements220-240, 1, 50 → 380-415, 3, 50
  • Cooling-capacity declarations and operating conditions-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7) → 16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
4 more differences
  • Efficiency declarations, methods and operating conditionsCOP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+ → COP 2.5 (A-7/W+55); COP 3.60 (A+2/W+35); COP 4.80 (A+7/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+
  • Operating ranges and mode conditions2,100; Male PT 1"; 675; R32; 15 ~ 80 → 5 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 35
  • Sound declarations and measurement basis220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39 → 43 dB(A); 63 / 60; 35 dB(A); 41 / 38
  • Dimensions and component basis490 × 850 × 315 (Indoor unit (W × H × D) (mm)); 950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm)) → 601 × 1,812 × 685 (Indoor unit (W × H × D) (mm)); 950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm))
Compare side by side
View details

Full comparison vs LG HN1616Y NB1 + HU121MRB U30

More details & evidence

Exact model: UK manufacturer configuration · HN1616Y NB1 + HU163MRB U30

Sources: 53 of 53 specifications cited.

Evidence · 100% source coverage

53/53 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
53
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeR32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Manufacturer heating capacities at separate operating points16 kW (A-7/W+55); 13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A-7/W+55) — Heating capacity (kW): 16; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Manufacturer refrigerant typeR32
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Manufacturer electrical supply requirements380-415, 3, 50
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1616Y NB1 + HU163MRB U30 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of R32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30
UK model

LG HN1600MC NK1 + HU121MRB U30

Compared with · LG HN1616Y NB1 + HU141MRB U30

  • Manufacturer unit type and installation roleR32 Hydrosplit IWT, 1Ø, 14kW HN1616Y NB1 + HU141MRB U30 → R32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30
  • Heating-capacity declarations and operating conditions11.50 kW (A-7/W+35); 14.00 kW (A-7/W+55); 12.00 kW (A+2/W+35); 14.00 kW (A+7/W+35); 14.00 kW (A+7/W+55) → 12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
  • Manufacturer refrigerant declarationMale PT 1" → R32
  • Cooling-capacity declarations and operating conditions-25 ~ 35 (A+35/W+18); 15 ~ 65 (A+35/W+7) → 12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
  • Efficiency declarations, methods and operating conditionsCOP 2.85 (A-7/W+35); COP 2.60 (A-7/W+55); COP 3.63 (A+2/W+35); COP 4.89 (A+7/W+35); COP 4.30 (A+7/W+55); EER 5 ~ 48 (A+35/W+18); EER 5 ~ 27 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 180 / 136; SCOP (35℃ / 55℃) 4.57 / 3.47; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+ → Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 181 / 137; SCOP (35℃ / 55℃) 4.60 / 3.50; COP 5.04 (A+7/W+35); COP 3.65 (A+2/W+35); COP 2.90 (A+7/W+55); EER 4.75 (A+35/W+18); EER 2,70 (A+35/W+7)
2 more differences
  • Operating ranges and mode conditions2,100; Male PT 1"; 675; R32; 15 ~ 80 → -25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80
  • Sound declarations and measurement basis220-240, 1, 50; White / RAL 9002; 36 dB(A); 41 / 39 → 61 / 60; 44 dB(A); 39 / 38; 36 dB(A)

Same: Electrical supply requirements 220-240, 1, 50

Compare side by side
View details

Full comparison vs LG HN1600MC NK1 + HU123MRB U30

More details & evidence

Exact model: UK manufacturer configuration · HN1600MC NK1 + HU121MRB U30

Sources: 45 of 45 specifications cited.

Evidence · 100% source coverage

45/45 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
45
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeR32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU121MRB U30 manufacturer specifications
Manufacturer heating capacities at separate operating points12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU121MRB U30 manufacturer specifications
Manufacturer refrigerant typeR32
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU121MRB U30 manufacturer specifications
Manufacturer electrical supply requirements220-240, 1, 50
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU121MRB U30 manufacturer specifications