Skip to specifications
versus.deals
Menu
Browse versus.deals
AIR CONDITIONING & HVAC UNITS

LG ZRUM180LTE6

UK configuration

Exact manufacturer unit purpose
Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 18HP, R32
Manufacturer heating capacities at separate operating points
50.4 kW; 172000; 56.7 kW; 193500
Manufacturer cooling capacities at separate operating points
50.4 kW; 172000

LG ZRUM180LTE6 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG ZRUM180LTE6 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of MULTI V i Heat Recovery Heat pump Outdoor Unit - ZRUM180LTE6.
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG ZRUM080LTE6

Specifications checked 20 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked air conditioning & hvac units by key specifications, with what differs from the LG ZRUM180LTE6. The first matches the Compare button above.

Front view of MULTI V i Heat Recovery Heat pump Outdoor Unit – ZRUM080LTE6.LG ZRUM080LTE6UK manufacturer configuration · ZRUM080LTE6
Exact manufacturer unit purpose
Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 8HP, R32This one: Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 18HP, R32
Manufacturer heating capacities at separate operating points
22.4 kW; 76400; 25.2 kW; 86000This one: 50.4 kW; 172000; 56.7 kW; 193500
Front view of MULTI V i Heat Recovery Heat pump Outdoor Unit – ZRUM100LTE6.LG ZRUM100LTE6UK manufacturer configuration · ZRUM100LTE6
Exact manufacturer unit purpose
Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 10HP, R32This one: Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 18HP, R32
Manufacturer heating capacities at separate operating points
28 kW; 95500; 31.5 kW; 107500This one: 50.4 kW; 172000; 56.7 kW; 193500
Front view of MULTI V i Heat Recovery Heat pump Outdoor Unit – ZRUM120LTE6.LG ZRUM120LTE6UK manufacturer configuration · ZRUM120LTE6
Exact manufacturer unit purpose
Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 12HP, R32This one: Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 18HP, R32
Manufacturer heating capacities at separate operating points
33.6 kW; 114600; 37.8 kW; 129000This one: 50.4 kW; 172000; 56.7 kW; 193500
The useful part.

Key strengths

The official LG UK page identifies manufacturer model ZRUM180LTE6.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · ZRUM180LTE6

73 specifications in 6 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 10 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

18 items
COOLING CAPACITY — Rated (kW)
50.4Source
COOLING CAPACITY — Rated (Btu/h)
172000Source
HEATING CAPACITY — Max (kW)
56.7Source
HEATING CAPACITY — Max (Btu/h)
193500Source
POWER INPUT(COOLING) — Rated (kW)
14.39Source
POWER INPUT(HEATING) — Rated (kW)
10.59Source
EFFICIENCY — EER(Rated) (W/W)
3.5Source
EFFICIENCY — COP(Rated) (W/W)
4.76Source
EFFICIENCY — SEER (Wh/Wh)
8.65Source
EFFICIENCY — SCOP (Wh/Wh)
4.81Source
POWER FACTOR(COOLING/HEATING) — Rated
0.93 / 0.93Source
COMPRESSOR — Type
Hermetically Sealed ScrollSource
COMPRESSOR — Piston Displacement (cm³/rev)
62.1 x 2Source
COMPRESSOR — Number of Revolution (rev./min)
3,600 x 2Source
COMPRESSOR — Motor Output (W x No.)
5,300 x 2Source
COMPRESSOR — Starting Method
InverterSource
COMPRESSOR — Oil Type
FW68L(PVE)Source
PROTECTION DEVICE — Compressor/Fan Protection
Over-heat protection / Fan driver overload protectorSource
Manufacturer wording (5)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer heating capacities at separate operating points
50.4 kW; 172000; 56.7 kW; 193500

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 50.4; HEATING CAPACITY — Rated (Btu/h): 172000; HEATING CAPACITY — Max (kW): 56.7; HEATING CAPACITY — Max (Btu/h): 193500. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
50.4 kW; 172000

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 50.4; COOLING CAPACITY — Rated (Btu/h): 172000. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer efficiency declarations and source methods
EER(Rated) (W/W) 3.5; COP(Rated) (W/W) 4.76; SEER (Wh/Wh) 8.65; SCOP (Wh/Wh) 4.81

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. EFFICIENCY — EER(Rated) (W/W): 3.5; EFFICIENCY — COP(Rated) (W/W): 4.76; EFFICIENCY — SEER (Wh/Wh): 8.65; EFFICIENCY — SCOP (Wh/Wh): 4.81. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
HEATING CAPACITY — Rated (kW)
50.4Source
HEATING CAPACITY — Rated (Btu/h)
172000Source

Refrigerant & circuit

5 items
REFRIGERANT — Type
R32Source
REFRIGERANT — Precharged amount (kg)
14Source
REFRIGERANT — GWP(Global Warming Potential)
675Source
REFRIGERANT — t-CO₂ eq.
9.45Source
REFRIGERANT — Control Type
EEVSource
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer refrigerant type
R32; EEV

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32; REFRIGERANT — Control Type: EEV. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Electrical supply & consumption

13 items
POWER SUPPLY — Case 1 (V, Phase, Hz)
380-400-415, 3, 50Source
POWER SUPPLY — Limit Range of Voltage(Case 1) (V)
342 ~ 456Source
POWER SUPPLY — Case 2 (V, Phase, Hz)
380, 3, 60Source
POWER SUPPLY — Limit Range of Voltage(Case 2) (V)
342 ~ 418Source
POWER SUPPLY — Running Current by Voltage (Cooling,Rated) (A)
23.51 - 22.34 - 21.53Source
POWER SUPPLY — Running Current by Voltage (Heating,Rated) (A)
17.30 - 16.44 - 15.84Source
ELECTRICAL CHARACTERISTIC — Minimium Circuit Amperes (MCA) (A)
44.8Source
ELECTRICAL CHARACTERISTIC — Maximum Fuse Amperes (MFA) (A)
50Source
ELECTRICAL CHARACTERISTIC — Total Over Current Amperes (TOCA) (A)
50Source
ELECTRICAL CHARACTERISTIC — Comp_Maximum Starting Current (MSC) (A)
11.8Source
ELECTRICAL CHARACTERISTIC — Comp_Rated Load Amperes (Cooling) (A)
21Source
ELECTRICAL CHARACTERISTIC — Comp_Rated Load Amperes (Heating) (A)
14.8Source
ELECTRICAL CHARACTERISTIC — Outdoor Fan Motor_Full Load Amperes (FLA) (A)
2.5Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer electrical supply requirements
380-400-415, 3, 50; 342 ~ 456; 380, 3, 60; 342 ~ 418

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Case 1 (V, Phase, Hz): 380-400-415, 3, 50; POWER SUPPLY — Limit Range of Voltage(Case 1) (V): 342 ~ 456; POWER SUPPLY — Case 2 (V, Phase, Hz): 380, 3, 60; POWER SUPPLY — Limit Range of Voltage(Case 2) (V): 342 ~ 418. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Installation, dimensions & airflow

29 items
Exact manufacturer unit purpose
Heat Pump-Heat Recovery Unit, Outdoor Unit, MULTI V, 18HP, R32

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
CLASSIFICATION — Chassis
UXBSource
CLASSIFICATION — Combination Unit (1)
ZRUM180LTE6Source
OUTDOOR FAN — Type
Propeller fanSource
OUTDOOR FAN — Air Flow Rate(High) (m³/min x No.)
320Source
OUTDOOR FAN — Max. External Static Pressure (Pa)
80Source
OUTDOOR FAN — Discharge direction(Side / Top)
TopSource
OUTDOOR FAN MOTOR — Type
BLDCSource
OUTDOOR FAN MOTOR — Drive
DirectSource
OUTDOOR FAN MOTOR — Output (W x No.)
900 x 2Source
HEAT EXCHANGER — Type
Fin & TubeSource
HEAT EXCHANGER — No.
1Source
HEAT EXCHANGER — Fin Type
Wide Louver PlusSource
DIMENSIONS — Net(W x H x D) (mm)
1,240 x 1,745 x 760Source
DIMENSIONS — Shipping(W x H x D) (mm)
1,282 x 1,919 x 802Source
WEIGHT — Net (kg)
305Source
WEIGHT — Shipping (kg)
315Source
EXTERIOR — Color
Morning Gray / Dawn GraySource
EXTERIOR — RAL (Classic)
RAL 7038 / RAL 7037Source
PROTECTION DEVICE — High Pressure Prevention
High pressure sensor / High pressure switchSource
CONNECTING PIPE — Liquid (mm(inch))
Φ12.7 (1/2)Source
CONNECTING PIPE — Gas (mm(inch))
Φ22.2 (7/8)Source
CONNECTING PIPE — High Pressure Gas (Heat Recovery) (mm(inch))
Φ19.05 (3/4)Source
PIPING CONNECTION TYPE — Liquid
BrazingSource
PIPING CONNECTION TYPE — Gas
BrazingSource
PIPING CONNECTION TYPE — Low Pressure Gas (Heat Recovery)
BrazingSource
PIPING CONNECTION TYPE — High Pressure Gas (Heat Recovery)
BrazingSource
MEASUREMENT STANDARD (PRESSURE LEVEL) — Measurement Standard (Pressure Level)
ISO 3745Source
CONNECTABLE INDOOR UNITS NUMBER — Max. (Conditional) (EA)
29(45)Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
1,240 x 1,745 x 760 mm

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Net(W x H x D) (mm).

Source
CONNECTING PIPE — Low Pressure Gas (Heat Recovery) (mm(inch))
Φ22.2 (7/8)Source

Operating conditions & sound

4 items
Manufacturer operating ranges and conditions
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer operating ranges and conditions. No value is inferred.

Source
SOUND PRESSURE LEVEL (OUTDOOR UNIT) — Cooling / Heating (dB(A))
61.0 / 62.0Source
SOUND POWER LEVEL (OUTDOOR UNIT) — Cooling / Heating (dB(A))
85.0 / 86.0Source
MEASUREMENT STANDARD (POWER LEVEL) — Measurement Standard (Power Level)
ISO 9614Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer sound declarations and measurement methods
61.0 / 62.0; 85.0 / 86.0

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND PRESSURE LEVEL (OUTDOOR UNIT) — Cooling / Heating (dB(A)): 61.0 / 62.0; SOUND POWER LEVEL (OUTDOOR UNIT) — Cooling / Heating (dB(A)): 85.0 / 86.0. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Controls & supplied items

4 items
PROTECTION DEVICE — Frost Prevention
O (Logical)Source
PROTECTION DEVICE — Discharge Temperature Control
O (Logical)Source
PROTECTION DEVICE — Inverter Protection
Over-heat protection / Over-current protectionSource
CONNECTING CABLE — Communication Cable(VCTF-SB) (mm² × cores)
1.0 x 2CSource
Similar products.

Compare with another air conditioning & hvac units product

More of the nearest checked air conditioning & hvac units by key specifications, for a side-by-side comparison.