The nearest checked air conditioning & hvac units by key specifications, with what differs from the LG ARWM080LAS5. The first matches the Compare button above.
Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
Exact configuration: UK manufacturer configuration · ARWM080LAS5
37 specifications in 6 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 10 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.
Heating, cooling & efficiency
14 items
Manufacturer efficiency declarations and source methods
Not listed by the manufacturer
The captured manufacturer specification table does not list an unambiguous manufacturer efficiency declarations and source methods. No value is inferred.
The same facts in the manufacturer’s combined or original wording, each with its source.
Manufacturer heating capacities at separate operating points
25.2 kW
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 25.2. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer cooling capacities at separate operating points
22.4 kW
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 22.4. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
The same facts in the manufacturer’s combined or original wording, each with its source.
Manufacturer refrigerant type
R410A; Electronic expansion valve
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R410A; REFRIGERANT — Control Type: Electronic expansion valve. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
The same facts in the manufacturer’s combined or original wording, each with its source.
Manufacturer electrical supply requirements
50 Hz 380-415 V 3N~; 380, 3, 60
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 380, 3, 60. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
MULTI V WATER 5, Water Heat Recovery, Outdoor Unit, 8HP, R410A
Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
The same facts in the manufacturer’s combined or original wording, each with its source.
Manufacturer dimensions and configuration basis
772 x 1120 x 547 mm
Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Net(W x H x D) (mm).
The same facts in the manufacturer’s combined or original wording, each with its source.
Manufacturer operating ranges and conditions
15 ~ 40; 15 ~ 40; 10 ~ 45; -5 ~ 45
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. CONTINUOUS OPERATION RANGE (INDOOR TEMP.) — Cooling (°C(WB)): 15 ~ 40; CONTINUOUS OPERATION RANGE (INDOOR TEMP.) — Heating (°C(DB)): 15 ~ 40; OPERATIVE RANGE (INDOOR TEMP.) — Cooling (°C(WB)): 10 ~ 45; OPERATIVE RANGE (INDOOR TEMP.) — Heating (°C(DB)): -5 ~ 45. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer sound declarations and measurement methods
45 / 48; 57 / 60
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND PRESSURE LEVEL (OUTDOOR UNIT) — Cooling / Heating (dB(A)): 45 / 48; SOUND POWER LEVEL (OUTDOOR UNIT) — Cooling / Heating (dB(A)): 57 / 60. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.