Skip to specifications
versus.deals
Menu
Browse versus.deals
AIR CONDITIONING & HVAC UNITS

LG ARNU24GTSC4

UK configuration

Exact manufacturer unit purpose
Ceiling Cassette, 2 Way, 24kBTU
Manufacturer heating capacities at separate operating points
8.00 kW
Manufacturer cooling capacities at separate operating points
7.10 kW

LG ARNU24GTSC4 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG ARNU24GTSC4 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of Ceiling Cassette, 2 Way, 24kBTU ARNU24GTSC4
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG ARNU24GL6G4

Specifications checked 20 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked air conditioning & hvac units by key specifications, with what differs from the LG ARNU24GTSC4. The first matches the Compare button above.

Front view of Concealed Duct, Low Static Duct, 24kBTU ARNU24GL6G4LG ARNU24GL6G4UK manufacturer configuration · ARNU24GL6G4
Exact manufacturer unit purpose
Concealed Duct, Low Static Duct, 24kBTUThis one: Ceiling Cassette, 2 Way, 24kBTU
Manufacturer sound declarations and measurement methods
- / 36.0 / 33.0 / 29.0; - / 36.0 / 33.0 / 29.0; - / 45.0 / 40.7 / 36.0; - / 45.0 / 40.7 / 36.0This one: - / 40 / 37 / 33; - / 40 / 37 / 33; - / 51 / 48 / 42; - / 51 / 48 / 42
Front view of Dual Vane Cassette, Indoor Unit, 24kBTU ARNU24GTBB4LG ARNU24GTBB4UK manufacturer configuration · ARNU24GTBB4
Exact manufacturer unit purpose
Dual Vane Cassette, Indoor Unit, 24kBTUThis one: Ceiling Cassette, 2 Way, 24kBTU
Manufacturer sound declarations and measurement methods
- / 39 / 37 / 35; - / 39 / 37 / 35; - / 46 / 44 / 42; - / 46 / 44 / 42This one: - / 40 / 37 / 33; - / 40 / 37 / 33; - / 51 / 48 / 42; - / 51 / 48 / 42
Front view of Round Cassette, Indoor Unit, 24kBTU ARNU24GTYA4LG ARNU24GTYA4UK manufacturer configuration · ARNU24GTYA4
Exact manufacturer unit purpose
Round Cassette, Indoor Unit, 24kBTUThis one: Ceiling Cassette, 2 Way, 24kBTU
Manufacturer sound declarations and measurement methods
- / 39 / 37 / 34; - / 39 / 37 / 34; - / 48 / 46 / 43; - / 48 / 46 / 43This one: - / 40 / 37 / 33; - / 40 / 37 / 33; - / 51 / 48 / 42; - / 51 / 48 / 42
The useful part.

Key strengths

The official LG UK page identifies manufacturer model ARNU24GTSC4.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · ARNU24GTSC4

18 specifications in 6 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 7 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

3 items
Manufacturer efficiency declarations and source methods
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer efficiency declarations and source methods. No value is inferred.

Source
COOLING CAPACITY — Nominal (kW)
7.10Source
HEATING CAPACITY — Nominal (kW)
8.00Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer heating capacities at separate operating points
8.00 kW

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Nominal (kW): 8.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
7.10 kW

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Nominal (kW): 7.10. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Refrigerant & circuit

1 item
Manufacturer refrigerant type
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer refrigerant type. No value is inferred.

Source

Electrical supply & consumption

2 items
POWER SUPPLY — #1
50 Hz 220-240 V~Source
POWER SUPPLY — #2
60 Hz 220 V~Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer electrical supply requirements
50 Hz 220-240 V~; 60 Hz 220 V~

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 220-240 V~; POWER SUPPLY — #2: 60 Hz 220 V~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Installation, dimensions & airflow

8 items
Exact manufacturer unit purpose
Ceiling Cassette, 2 Way, 24kBTU

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
INDOOR FAN — Air Flow Rate(Cooling,(SH)/H/M/L) (m³/min)
- / 14.5 / 12.4 / 10.3Source
DRAIN PIPE(USING DRAIN PUMP) — O.D / I.D (mm(inch))
25(1)Source
PRODUCT — Type
Ceiling CassetteSource
DIMENSIONS — Net(W x H x D) (mm)
830 x 225 x 600Source
WEIGHT — Net (kg)
18.1Source
CONNECTING PIPE — Liquid (mm(inch))
Φ9.52 (3/8)Source
CONNECTING PIPE — Gas (mm(inch))
Φ15.88 (5/8)Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
830 x 225 x 600 mm

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Net(W x H x D) (mm).

Source

Operating conditions & sound

3 items
Manufacturer operating ranges and conditions
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer operating ranges and conditions. No value is inferred.

Source
SOUND PRESSURE LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A))
- / 40 / 37 / 33Source
SOUND POWER LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A))
- / 51 / 48 / 42Source
Manufacturer wording (3)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer sound declarations and measurement methods
- / 40 / 37 / 33; - / 40 / 37 / 33; - / 51 / 48 / 42; - / 51 / 48 / 42

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND PRESSURE LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A)): - / 40 / 37 / 33; SOUND PRESSURE LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A)): - / 40 / 37 / 33; SOUND POWER LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A)): - / 51 / 48 / 42; SOUND POWER LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A)): - / 51 / 48 / 42. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
SOUND PRESSURE LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A))
- / 40 / 37 / 33Source
SOUND POWER LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A))
- / 51 / 48 / 42Source

Model, type & source

1 item
DECORATION PANEL — Model Name
PT-USCSource
Similar products.

Compare with another air conditioning & hvac units product

More of the nearest checked air conditioning & hvac units by key specifications, for a side-by-side comparison.