AIR CONDITIONING & HVAC UNITS

LG ARNU05GL4G4

UK configuration

Exact manufacturer unit purpose
Concealed Duct, Low Static Duct, 6kBTU
Manufacturer heating capacities at separate operating points
2.20 kW
Manufacturer cooling capacities at separate operating points
1.80 kW

LG ARNU05GL4G4 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG ARNU05GL4G4 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of Concealed Duct, Low Static Duct, 6kBTU ARNU05GL4G4
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG ARNU05GTRB4

Specifications checked 20 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked air conditioning & hvac units by key specifications, with what differs from the LG ARNU05GL4G4. The first matches the Compare button above.

The useful part.

Key strengths

The official LG UK page identifies manufacturer model ARNU05GL4G4.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · ARNU05GL4G4

18 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 7 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

3 items
Manufacturer efficiency declarations and source methods
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer efficiency declarations and source methods. No value is inferred.

Source
COOLING CAPACITY — Nominal (kW)
1.80Source
HEATING CAPACITY — Nominal (kW)
2.20Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer heating capacities at separate operating points
2.20 kW

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Nominal (kW): 2.20. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
1.80 kW

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Nominal (kW): 1.80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Refrigerant & circuit

1 item
Manufacturer refrigerant type
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer refrigerant type. No value is inferred.

Source

Electrical supply & consumption

2 items
POWER SUPPLY — #1
50 Hz 220-240 V~Source
POWER SUPPLY — #2
60 Hz 220 V~Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer electrical supply requirements
50 Hz 220-240 V~; 60 Hz 220 V~

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 220-240 V~; POWER SUPPLY — #2: 60 Hz 220 V~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Installation, dimensions & airflow

9 items
Exact manufacturer unit purpose
Concealed Duct, Low Static Duct, 6kBTU

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
INDOOR FAN — Air Flow Rate(Cooling,(SH)/H/M/L) (m³/min)
- / 7.0 / 6.5 / 5.5Source
INDOOR FAN — External Static Pressure(Factory Set) (Pa)
10Source
DRAIN PIPE(USING DRAIN PUMP) — O.D / I.D (mm(inch))
- / 25.4(1)Source
PRODUCT — Type
Concealed DuctSource
DIMENSIONS — Net(W x H x D) (mm)
700 x 190 x 460Source
WEIGHT — Net (kg)
14.6Source
CONNECTING PIPE — Liquid (mm(inch))
Φ6.35 (1/4)Source
CONNECTING PIPE — Gas (mm(inch))
Φ12.7 (1/2)Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
700 x 190 x 460 mm

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Net(W x H x D) (mm).

Source

Operating conditions & sound

3 items
Manufacturer operating ranges and conditions
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer operating ranges and conditions. No value is inferred.

Source
SOUND PRESSURE LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A))
- / 25.0 / 24.0 / 22.0Source
SOUND POWER LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A))
- / 32.5 / 31.4 / 29.6Source
Manufacturer wording (3)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer sound declarations and measurement methods
- / 25.0 / 24.0 / 22.0; - / 25.0 / 24.0 / 22.0; - / 32.5 / 31.4 / 29.6; - / 32.5 / 31.4 / 29.6

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND PRESSURE LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A)): - / 25.0 / 24.0 / 22.0; SOUND PRESSURE LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A)): - / 25.0 / 24.0 / 22.0; SOUND POWER LEVEL (INDOOR UNIT) — Cooling((SH)/H/M/L) (dB(A)): - / 32.5 / 31.4 / 29.6; SOUND POWER LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A)): - / 32.5 / 31.4 / 29.6. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
SOUND PRESSURE LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A))
- / 25.0 / 24.0 / 22.0Source
SOUND POWER LEVEL (INDOOR UNIT) — Heating((SH)/H/M/L) (dB(A))
- / 32.5 / 31.4 / 29.6Source