Skip to specifications
versus.deals
Menu
Browse versus.deals
AIR CONDITIONING & HVAC UNITS

LG ARNH04GK2A4

UK configuration

Exact manufacturer unit purpose
MULTI V Hydro Kit, Floor type - Mid Temperature, 14kW
Manufacturer heating capacities at separate operating points
13.8 kW
Manufacturer cooling capacities at separate operating points
12.3 kW

LG ARNH04GK2A4 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG ARNH04GK2A4 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of MULTI V Hydro Kit, Floor type - Mid Temperature, 14kW ARNH04GK2A4
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG ARNH04GK3A4

Specifications checked 20 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked air conditioning & hvac units by key specifications, with what differs from the LG ARNH04GK2A4. The first matches the Compare button above.

The useful part.

Key strengths

The official LG UK page identifies manufacturer model ARNH04GK2A4.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · ARNH04GK2A4

19 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 8 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

4 items
Manufacturer efficiency declarations and source methods
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer efficiency declarations and source methods. No value is inferred.

Source
COOLING CAPACITY — Rated (kW)
12.3Source
HEATING CAPACITY — Rated (kW)
13.8Source
POWER INPUT(COOLING) — Rated (kW)
0.01Source
Manufacturer wording (3)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer heating capacities at separate operating points
13.8 kW

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 13.8. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
12.3 kW

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 12.3. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
POWER INPUT(HEATING) — Rated (kW)
0.01Source

Refrigerant & circuit

3 items
REFRIGERANT — Type
R410ASource
REFRIGERANT — GWP(Global Warming Potential)
2087.5Source
REFRIGERANT — Control Type
Electronic Expansion ValveSource
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer refrigerant type
R410A; Electronic Expansion Valve

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R410A; REFRIGERANT — Control Type: Electronic Expansion Valve. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source

Electrical supply & consumption

1 item
Manufacturer electrical supply requirements
50/60 Hz 220-240 V~

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50/60 Hz 220-240 V~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

POWER SUPPLY — #1
50/60 Hz 220-240 V~Source

Installation, dimensions & airflow

9 items
Exact manufacturer unit purpose
MULTI V Hydro Kit, Floor type - Mid Temperature, 14kW

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
HEAT EXCHANGER — Type
Brazed Plate HEXSource
HEAT EXCHANGER — Head loss ( kPa )
41Source
HEAT EXCHANGER — Rated Water Flow ( LPM )
39.6Source
DIMENSIONS — Net(W x H x D) (mm)
520 x 631 x 330Source
WEIGHT — Net (kg)
29.2Source
CONNECTING PIPE — Liquid (mm(inch))
Ø 9.52(3/8)Source
CONNECTING PIPE — Gas (mm(inch))
Ø 15.88(5/8)Source
WATER CONNECTING PIPES — Inlet (inch)
Male PT 1Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
520 x 631 x 330 mm

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Net(W x H x D) (mm).

Source
WATER CONNECTING PIPES — Outlet (inch)
Male PT 1Source

Operating conditions & sound

2 items
Manufacturer operating ranges and conditions
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer operating ranges and conditions. No value is inferred.

Source
Manufacturer sound declarations and measurement methods
26/26

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND PRESSURE LEVEL — Cooling / Heating (dB(A)): 26/26. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

SOUND PRESSURE LEVEL — Cooling / Heating (dB(A))
26/26Source
Similar products.

Compare with another air conditioning & hvac units product

More of the nearest checked air conditioning & hvac units by key specifications, for a side-by-side comparison.