LG HN1610H NK3 + HU161HA U33

UK configuration

Exact manufacturer unit purpose
High Temperature, 1Ø, 16kW HN1610H NK3 + HU161HA U33
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 16.00 kW (A+2/W+35); 14.00 kW (A+7/W+55)
Manufacturer efficiency declarations and source methods
COP 3.27 (A+7/W+35); COP 3.25 (A+2/W+35); COP 2.78 (A+7/W+55); SCOP (35℃ / 55℃) 3.23 / 3.01; Seasonal space heating eff. class (35℃ / 55℃) A+/A+; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 126 / 117

LG HN1610H NK3 + HU161HA U33 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG HN1610H NK3 + HU161HA U33 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of High Temperature, 1Ø, 16kW HN1610H NK3 + HU161HA U33
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG HM051MR U44

Specifications checked 19 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked heat pumps by key specifications, with what differs from the LG HN1610H NK3 + HU161HA U33. The first matches the Compare button above.

Front view of R32 Monobloc S, 1Ø, 5kW HM051MR U44LG HM051MR U44UK manufacturer configuration · HM051MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 5kW HM051MR U44This one: High Temperature, 1Ø, 16kW HN1610H NK3 + HU161HA U33
Manufacturer heating capacities at separate operating points
4.40 kW (A+2/W+35); 5.50 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 16.00 kW (A+7/W+35); 16.00 kW (A+2/W+35); 14.00 kW (A+7/W+55)
Front view of R32 Monobloc S, 1Ø, 7kW HM071MR U44LG HM071MR U44UK manufacturer configuration · HM071MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 7kW HM071MR U44This one: High Temperature, 1Ø, 16kW HN1610H NK3 + HU161HA U33
Manufacturer heating capacities at separate operating points
5.60 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 16.00 kW (A+7/W+35); 16.00 kW (A+2/W+35); 14.00 kW (A+7/W+55)
Front view of R32 Monobloc S, 1Ø, 9kW HM091MR U44LG HM091MR U44UK manufacturer configuration · HM091MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 9kW HM091MR U44This one: High Temperature, 1Ø, 16kW HN1610H NK3 + HU161HA U33
Manufacturer heating capacities at separate operating points
6.80 kW (A+2/W+35); 9.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 16.00 kW (A+7/W+35); 16.00 kW (A+2/W+35); 14.00 kW (A+7/W+55)
The useful part.

Key strengths

The official LG UK page identifies manufacturer model HN1610H NK3 + HU161HA U33.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · HN1610H NK3 + HU161HA U33

36 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 7 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

11 items
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 16.00 kW (A+2/W+35); 14.00 kW (A+7/W+55)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 14.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
Not listed by the manufacturer

The captured manufacturer specification table does not list an unambiguous manufacturer cooling capacities at separate operating points. No value is inferred.

Source
Manufacturer efficiency declarations and source methods
COP 3.27 (A+7/W+35); COP 3.25 (A+2/W+35); COP 2.78 (A+7/W+55); SCOP (35℃ / 55℃) 3.23 / 3.01; Seasonal space heating eff. class (35℃ / 55℃) A+/A+; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 126 / 117

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 3.27; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.25; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.78; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 3.23 / 3.01; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+/A+; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 126 / 117. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
3.27Source
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
16.00Source
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
3.25Source
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
2.78Source
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
14.00Source
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
3.23 / 3.01Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
A+/A+Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
126 / 117Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
16.00Source

Refrigerant & circuit

3 items
Manufacturer refrigerant type
(ODU) R410A / (IDU) R134a

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: (ODU) R410A / (IDU) R134a. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
REFRIGERANT — GWP
(ODU) 2,088 / (IDU) 1,430Source
REFRIGERANT — Precharged amount (g)
(ODU) 3,800 / (IDU) 1,800Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

REFRIGERANT — Type
(ODU) R410A / (IDU) R134aSource

Electrical supply & consumption

1 item
Manufacturer electrical supply requirements
220-240, 1, 50

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
220-240, 1, 50Source

Installation, dimensions & airflow

14 items
Exact manufacturer unit purpose
High Temperature, 1Ø, 16kW HN1610H NK3 + HU161HA U33

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))
Ø 15.88 (5/8)Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))
Ø 9.52 (3/8)Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)
7.5 / 50Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)
30Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)
7.5Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)
40Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)
Male PT 1"Source
DIMENSIONS — Outdoor unit (W × H × D) (mm)
950 × 1,380 × 330Source
DIMENSIONS — Indoor unit (W × H × D) (mm)
520 x 1,080 x 330Source
WEIGHT — Outdoor unit (Empty) (kg)
89.0Source
WEIGHT — Indoor unit (Empty) (kg)
84.0Source
EXTERIOR — Outdoor unit (Color / RAL code)
Warm gray / RAL 7044Source
EXTERIOR — Indoor unit (Color / RAL code)
Morning gray / RAL 7030Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 520 x 1,080 x 330 (Indoor unit (W × H × D) (mm))

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)
Male PT 1"Source

Operating conditions & sound

7 items
Manufacturer sound declarations and measurement methods
41 / -; 50 dB(A); 63 / -; 58 dB(A)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / -; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 50; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / -; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 58. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
41 / -Source
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))
50Source
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
63 / -Source
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))
58Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
-25 ~ 35Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
25 ~ 80Source
Manufacturer wording (2)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer operating ranges and conditions
-25 ~ 35; 25 ~ 80; 25 ~ 80

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 25 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 25 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
25 ~ 80Source