R32 Split 5/7/9 kW IWT, 1Ø, 7kW HN0913T NK0 + HU071MR U44
Manufacturer heating capacities at separate operating points
4.20 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
7.00 kW (A+35/W+18); 7.00 kW (A+35/W+7)

LG HN0913T NK0 + HU071MR U44 in the exact manufacturer-listed UK configuration.

Prices & buying options

Search links open retailer results.

UK: no verified listing yet · checked daily

US: no verified listing yet · checked daily

As an eBay Partner, we may be compensated if you make a purchase.

Affiliate links

We may earn a commission. Search results can include other models; check the exact variant and final price with the retailer.

As an Amazon Associate I earn from qualifying purchases.

Price alert

Email me when the LG HN0913T NK0 + HU071MR U44 gets cheaper on eBay. We check exact-model listings once a day at 12:00 UTC.

We'll send a link to confirm first.

THE ACTUAL PRODUCT
Front view of R32 Split 5/7/9 kW IWT, 1Ø, 7kW HN0913T NK0 + HU071MR U44
Official product image · Image source detailsProduct imagery does not establish a retailer’s bundle or condition.
Compare with LG HN091MR NK5 + HU071MR U44

Specifications checked 19 Oct 2026Manufacturer specifications, not a hands-on test.

Options worth comparing

Explore all alternatives

The nearest checked heat pumps by key specifications, with what differs from the LG HN0913T NK0 + HU071MR U44. The first matches the Compare button above.

Front view of R32 Split 5/7/9 kW Hydro Box, 1Ø, 7kW HN091MR NK5 + HU071MR U44LG HN091MR NK5 + HU071MR U44UK manufacturer configuration · HN091MR NK5 + HU071MR U44
Exact manufacturer unit purpose
R32 Split 5/7/9 kW Hydro Box, 1Ø, 7kW HN091MR NK5 + HU071MR U44This one: R32 Split 5/7/9 kW IWT, 1Ø, 7kW HN0913T NK0 + HU071MR U44
Manufacturer efficiency declarations and source methods
COP 3.51 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.50 (A+35/W+18); EER 2.70 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 183 / 126; SCOP (35℃ / 55℃) 4.65 / 3.23; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++This one: COP 3.51 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.50 (A+35/W+18); EER 2.70 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 183 / 126; SCOP (35℃ / 55℃) 4.65 / 3.23; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 133; Water heating eff. class, average climate A+
Front view of R32 Monobloc S, 1Ø, 5kW HM051MR U44LG HM051MR U44UK manufacturer configuration · HM051MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 5kW HM051MR U44This one: R32 Split 5/7/9 kW IWT, 1Ø, 7kW HN0913T NK0 + HU071MR U44
Manufacturer heating capacities at separate operating points
4.40 kW (A+2/W+35); 5.50 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 4.20 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)
Front view of R32 Monobloc S, 1Ø, 7kW HM071MR U44LG HM071MR U44UK manufacturer configuration · HM071MR U44
Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 7kW HM071MR U44This one: R32 Split 5/7/9 kW IWT, 1Ø, 7kW HN0913T NK0 + HU071MR U44
Manufacturer heating capacities at separate operating points
5.60 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)This one: 4.20 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)
The useful part.

Key strengths

The official LG UK page identifies manufacturer model HN0913T NK0 + HU071MR U44.

The checks that matter.

Before you buy

Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

Every specification. With its source.

Full specifications

Exact configuration: UK manufacturer configuration · HN0913T NK0 + HU071MR U44

45 specifications in 5 groups. Values are manufacturer specifications unless a row says “Measured result” or “Calculated from cited specifications”. 11 rows repeat listed facts in the manufacturer’s own wording, kept under “Manufacturer wording”.

Heating, cooling & efficiency

17 items
Manufacturer heating capacities at separate operating points
4.20 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 4.20; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 7.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer cooling capacities at separate operating points
7.00 kW (A+35/W+18); 7.00 kW (A+35/W+7)

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 7.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 7.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer efficiency declarations and source methods
COP 3.51 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.50 (A+35/W+18); EER 2.70 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 183 / 126; SCOP (35℃ / 55℃) 4.65 / 3.23; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 133; Water heating eff. class, average climate A+

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.51; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.90; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.50; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.70; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 183 / 126; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.65 / 3.23; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 133; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
3.51Source
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
4.20Source
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
4.90Source
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
7.00Source
NOMINAL CAPACITY AND COP (A+7/W+55) — COP
2.70Source
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
5.50Source
NOMINAL CAPACITY AND EER (A+35/W+18) — EER
4.50Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
183 / 126Source
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)
4.65 / 3.23Source
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
A+++/A++Source
WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate
133Source
WATER HEATING EFFICIENCY DATA — COPDHW, average climate
3.15Source
WATER HEATING EFFICIENCY DATA — Declared load profile, average climate
LSource
WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate
A+Source
Manufacturer wording (3)

The same facts in the manufacturer’s combined or original wording, each with its source.

NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)
7.00Source
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)
7.00Source
NOMINAL CAPACITY AND EER (A+35/W+7) — EER
2.70Source

Refrigerant & circuit

3 items
Manufacturer refrigerant type
R32

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
REFRIGERANT — GWP
675Source
REFRIGERANT — Precharged amount (g)
1,500Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

REFRIGERANT — Type
R32Source

Electrical supply & consumption

1 item
Manufacturer electrical supply requirements
220-240, 1, 50

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
220-240, 1, 50Source

Installation, dimensions & airflow

14 items
Exact manufacturer unit purpose
R32 Split 5/7/9 kW IWT, 1Ø, 7kW HN0913T NK0 + HU071MR U44

Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Source
DIMENSIONS — Indoor unit (W × H × D) (mm)
600 × 1,750 × 660Source
DIMENSIONS — Outdoor unit (W × H × D) (mm)
950 × 834 × 330Source
EXTERIOR — Indoor unit (Color / RAL code)
White / RAL 9016Source
EXTERIOR — Outdoor unit (Color / RAL code)
Warm gray / RAL 7044Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))
Ø 15.88 (5/8)Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)
5 / 50Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)
30Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))
Ø 9.52 (3/8)Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)
40Source
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)
10Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)
Female G1"Source
WEIGHT — Indoor unit (Empty) (kg)
118.0Source
WEIGHT — Outdoor unit (Empty) (kg)
60.0Source
Manufacturer wording (5)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer dimensions and configuration basis
600 × 1,750 × 660 (Indoor unit (W × H × D) (mm)); 950 × 834 × 330 (Outdoor unit (W × H × D) (mm))

Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for DHW (inch)
Female G1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for DHW (inch)
Female G1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)
Female G1"Source
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)
Female G1"Source

Operating conditions & sound

10 items
Manufacturer sound declarations and measurement methods
42 dB(A); 60 / 58; 34 dB(A); 38 / 36

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 42; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 60 / 58; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 34; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 38 / 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
5 ~ 27Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
15 ~ 80Source
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
15 ~ 65Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
5 ~ 48Source
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
-25 ~ 35Source
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))
42Source
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
60 / 58Source
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))
34Source
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
38 / 36Source
Manufacturer wording (1)

The same facts in the manufacturer’s combined or original wording, each with its source.

Manufacturer operating ranges and conditions
5 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 35

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

Source
Similar products.

Compare with another heat pumps product

More of the nearest checked heat pumps by key specifications, for a side-by-side comparison.