YOUR FIRST CHOICE

LG HN1600MC NK1 + HU163MRB U30

UK manufacturer configuration · HN1600MC NK1 + HU163MRB U30

Front view of R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30
Exact model & source notes

LG HN1600MC NK1 + HU163MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
Manufacturer refrigerant typeR32R410A
NOMINAL CAPACITY AND COP (A+7/W+35) — COP4.804.26
NOMINAL CAPACITY AND COP (A+7/W+55) — COP2.802.55
3 of 22 verified differences, in the order listed below. Not a rating.
See the 22 verified differences
THE CONTENDER

LG HN1636M NK5 + HU163MA U33

UK manufacturer configuration · HN1636M NK5 + HU163MA U33

Front view of R410A Split Hydro Box, 3Ø, 16kW HN1636M NK5 + HU163MA U33
Exact model & source notes

LG HN1636M NK5 + HU163MA U33 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HN1600MC NK1 + HU163MRB U30 UK & US retailers

UK & US price history: no verified listing yet

HN1636M NK5 + HU163MA U33 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE7 topics
SELECTED TOPIC
01 / 07

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HN1636M NK5 + HU163MA U33R410A Split Hydro Box, 3Ø, 16kW HN1636M NK5 + HU163MA U33

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

22 verified differences, most decision-relevant first. 7 are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HN1600MC NK1 + HU163MRB U30R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30
LG HN1636M NK5 + HU163MA U33R410A Split Hydro Box, 3Ø, 16kW HN1636M NK5 + HU163MA U33
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer cooling capacities at separate operating points

In Visual facts
LG HN1600MC NK1 + HU163MRB U3016.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
LG HN1636M NK5 + HU163MA U3313.00 kW (A+35/W+18); 8.92 kW (A+35/W+7)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 13.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 8.92. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer efficiency declarations and source methods

In Visual facts
LG HN1600MC NK1 + HU163MRB U30Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)
LG HN1636M NK5 + HU163MA U33Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 130; SCOP (35℃ / 55℃) 4.56 / 3.32; COP 4.26 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.55 (A+7/W+55); EER 3.61 (A+35/W+18); EER 3.53 (A+35/W+7)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 130; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.56 / 3.32; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.26; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.55; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 3.61; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.53. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer refrigerant type

In Visual facts
LG HN1600MC NK1 + HU163MRB U30R32
LG HN1636M NK5 + HU163MA U33R410A
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R410A. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer operating ranges and conditions

In Visual facts
LG HN1600MC NK1 + HU163MRB U305 ~ 48; -25 ~ 35; 15 ~ 65; 5 ~ 27; 15 ~ 80
LG HN1636M NK5 + HU163MA U33-25 ~ 35; 5 ~ 48; 5 ~ 48; 5 ~ 27; 15 ~ 80
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer sound declarations and measurement methods

In Visual facts
LG HN1600MC NK1 + HU163MRB U3063 / 60; 44 dB(A); 41 / 38; 36 dB(A)
LG HN1636M NK5 + HU163MA U3365 / 63; 44 dB(A); 43 / 41; 36 dB(A)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 65 / 63; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 43 / 41; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Check the exact configuration and source conditions for your use.

Show 16 more verified differences
Missing or non-comparable evidence (12)

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U33Ø 15.88 (5/8)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U337.5 / 30
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U3330
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U33Ø 9.52 (3/8)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U3340
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U337.5
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U33Male PT 1"
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)

LG HN1600MC NK1 + HU163MRB U30Male PT 1"
LG HN1636M NK5 + HU163MA U33Not verified
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)

LG HN1600MC NK1 + HU163MRB U30Male PT 1"
LG HN1636M NK5 + HU163MA U33Not verified
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)

LG HN1600MC NK1 + HU163MRB U30Not verified
LG HN1636M NK5 + HU163MA U33Male PT 1"
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded for this side.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)

LG HN1600MC NK1 + HU163MRB U30Male PT 1"
LG HN1636M NK5 + HU163MA U33Not verified
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)

LG HN1600MC NK1 + HU163MRB U30Male PT 1"
LG HN1636M NK5 + HU163MA U33Not verified
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

19 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HN1600MC NK1 + HU163MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1600MC NK1 + HU163MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HN1636M NK5 + HU163MA U33

What it brings

  • The official LG UK page identifies manufacturer model HN1636M NK5 + HU163MA U33.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
53 of 53 specifications Sources in each row
Source-backed specifications for LG HN1600MC NK1 + HU163MRB U30 and LG HN1636M NK5 + HU163MA U33
SpecificationLG HN1600MC NK1 + HU163MRB U30LG HN1636M NK5 + HU163MA U33
Manufacturer heating capacities at separate operating points
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating pointsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 16.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 13.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 8.92. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)13.00 kW (A+35/W+18); 8.92 kW (A+35/W+7)
Manufacturer efficiency declarations and source methodsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 135; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.55 / 3.45; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.80; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.00; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 179 / 130; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.56 / 3.32; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.26; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.60; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.55; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 3.61; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.53. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; SCOP (35℃ / 55℃) 4.55 / 3.45; COP 4.80 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7)Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 130; SCOP (35℃ / 55℃) 4.56 / 3.32; COP 4.26 (A+7/W+35); COP 3.60 (A+2/W+35); COP 2.55 (A+7/W+55); EER 3.61 (A+35/W+18); EER 3.53 (A+35/W+7)
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
179 / 135179 / 130
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
A+++/A++A+++/A++
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
4.55 / 3.454.56 / 3.32
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
16.0016.00
NOMINAL CAPACITY AND COP (A+7/W+35) — COPDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
4.804.26
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
13.8013.80
NOMINAL CAPACITY AND COP (A+2/W+35) — COP
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
3.603.60
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
12.0012.00
NOMINAL CAPACITY AND COP (A+7/W+55) — COPDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
2.802.55
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
16.0013.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EERDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
4.003.61
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
16.008.92
NOMINAL CAPACITY AND EER (A+35/W+7) — EERDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
2.503.53
Manufacturer refrigerant typeDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R410A. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
R32R410A
REFRIGERANT — TypeDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
R32R410A
REFRIGERANT — GWPDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
6752,088
REFRIGERANT — Precharged amount (g)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
2,1002,500
Manufacturer electrical supply requirements
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
380-415, 3, 50380-415, 3, 50
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
380-415, 3, 50380-415, 3, 50
Exact manufacturer unit purposeDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
R32 Hydrosplit Hydro Box, 3Ø, 16kW HN1600MC NK1 + HU163MRB U30R410A Split Hydro Box, 3Ø, 16kW HN1636M NK5 + HU163MA U33
Manufacturer dimensions and configuration basis
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))950 x 1,380 x 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded.

Male PT 1"Not provided
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded.

Male PT 1"Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded.

Male PT 1"Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

No source recorded.

Male PT 1"Not provided
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
950 × 1,380 × 330950 x 1,380 x 330
DIMENSIONS — Indoor unit (W × H × D) (mm)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
490 × 850 × 315490 × 850 × 315
WEIGHT — Outdoor unit (Empty) (kg)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
91.785.4
WEIGHT — Indoor unit (Empty) (kg)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
30.541.5
EXTERIOR — Outdoor unit (Color / RAL code)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Warm gray / RAL 7044Warm gray / RAL 7044
EXTERIOR — Indoor unit (Color / RAL code)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Noble white / RAL 9016Noble white / RAL 9016
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not providedØ 15.88 (5/8)
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not provided7.5 / 30
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not provided30
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not providedØ 9.52 (3/8)
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not provided40
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not provided7.5
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not providedMale PT 1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)
Sources
LG HN1600MC NK1 + HU163MRB U30

No source recorded.

LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
Not providedMale PT 1"
Manufacturer operating ranges and conditionsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
5 ~ 48; -25 ~ 35; 15 ~ 65; 5 ~ 27; 15 ~ 80-25 ~ 35; 5 ~ 48; 5 ~ 48; 5 ~ 27; 15 ~ 80
Manufacturer sound declarations and measurement methodsDifferent
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 63 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 41 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 65 / 63; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 43 / 41; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
63 / 60; 44 dB(A); 41 / 38; 36 dB(A)65 / 63; 44 dB(A); 43 / 41; 36 dB(A)
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
-25 ~ 35-25 ~ 35
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
15 ~ 655 ~ 48
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
15 ~ 8015 ~ 80
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
63 / 6065 / 63
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
4444
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))Different
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
41 / 3843 / 41
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))
Sources
LG HN1600MC NK1 + HU163MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU163MRB U30 manufacturer specifications
LG HN1636M NK5 + HU163MA U33

Manufacturer specification

LG UK — HN1636M NK5 + HU163MA U33 manufacturer specifications
3636
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30

LG HN1600MC NK1 + HU161MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 16kW HN1600MC NK1 + HU161MRB U30
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 3Ø, 16kW HM163MR U34

LG HM163MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 3Ø, 16kW HM163MR U34
Manufacturer heating capacities at separate operating points
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+7); 16.00 kW (A+35/W+18)
Prices & product profile
Front view of R410A Split Hydro Box, 1Ø, 16kW HN1616M NK5 + HU161MA U33

LG HN1616M NK5 + HU161MA U33

Exact manufacturer unit purpose
R410A Split Hydro Box, 1Ø, 16kW HN1616M NK5 + HU161MA U33
Manufacturer heating capacities at separate operating points
13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
13.00 kW (A+35/W+18); 8.92 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S II, 3Ø, 16kW HM163MRS UB40

LG HM163MRS UB40

Exact manufacturer unit purpose
R32 Monobloc S II, 3Ø, 16kW
Manufacturer heating capacities at separate operating points
13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)
Prices & product profile

Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.