Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HN0913T NK0 + HU051MR U44 vs LG HN1600MC NK1 + HU123MRB U30

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HN0913T NK0 + HU051MR U44

UK manufacturer configuration · HN0913T NK0 + HU051MR U44

Front view of R32 Split 5/7/9 kW IWT, 1Ø, 5kW HN0913T NK0 + HU051MR U44
Exact model & source notes

LG HN0913T NK0 + HU051MR U44 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
Manufacturer electrical supply requirements220-240, 1, 50380-415, 3, 50
DIMENSIONS — Indoor unit (W × H × D) (mm)600 × 1,750 × 660490 × 850 × 315
DIMENSIONS — Outdoor unit (W × H × D) (mm)950 × 834 × 330950 × 1,380 × 330
3 of 30 verified differences, in the order listed below. Not a rating.
See the 30 verified differences
THE CONTENDER

LG HN1600MC NK1 + HU123MRB U30

UK manufacturer configuration · HN1600MC NK1 + HU123MRB U30

Front view of R32 Hydrosplit Hydro Box, 3Ø, 12kW HN1600MC NK1 + HU123MRB U30
Exact model & source notes

LG HN1600MC NK1 + HU123MRB U30 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HN0913T NK0 + HU051MR U44 UK & US retailers

UK & US price history: no verified listing yet

HN1600MC NK1 + HU123MRB U30 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE7 topics
SELECTED TOPIC
01 / 07

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HN0913T NK0 + HU051MR U44R32 Split 5/7/9 kW IWT, 1Ø, 5kW HN0913T NK0 + HU051MR U44

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HN1600MC NK1 + HU123MRB U30R32 Hydrosplit Hydro Box, 3Ø, 12kW HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

30 verified differences, most decision-relevant first. 7 are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HN0913T NK0 + HU051MR U44R32 Split 5/7/9 kW IWT, 1Ø, 5kW HN0913T NK0 + HU051MR U44
LG HN1600MC NK1 + HU123MRB U30R32 Hydrosplit Hydro Box, 3Ø, 12kW HN1600MC NK1 + HU123MRB U30
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer heating capacities at separate operating points

In Visual facts
LG HN0913T NK0 + HU051MR U443.30 kW (A+2/W+35); 5.50 kW (A+7/W+35); 5.50 kW (A+7/W+55)
LG HN1600MC NK1 + HU123MRB U3012.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 3.30; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 5.50; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer cooling capacities at separate operating points

In Visual facts
LG HN0913T NK0 + HU051MR U445.50 kW (A+35/W+18); 5.50 kW (A+35/W+7)
LG HN1600MC NK1 + HU123MRB U3012.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 5.50; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 12.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer efficiency declarations and source methods

In Visual facts
LG HN0913T NK0 + HU051MR U44COP 3.52 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.60 (A+35/W+18); EER 2.80 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 183 / 126; SCOP (35℃ / 55℃) 4.65 / 3.23; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 133; Water heating eff. class, average climate A+
LG HN1600MC NK1 + HU123MRB U30Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 181 / 137; SCOP (35℃ / 55℃) 4.60 / 3.50; COP 5.04 (A+7/W+35); COP 3.65 (A+2/W+35); COP 2.90 (A+7/W+55); EER 4.75 (A+35/W+18); EER 2,70 (A+35/W+7)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.52; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.90; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.60; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.80; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 183 / 126; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.65 / 3.23; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 133; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 181 / 137; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.60 / 3.50; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 5.04; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.65; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.90; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.75; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2,70. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer electrical supply requirements

In Visual facts
LG HN0913T NK0 + HU051MR U44220-240, 1, 50
LG HN1600MC NK1 + HU123MRB U30380-415, 3, 50
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer sound declarations and measurement methods

In Visual facts
LG HN0913T NK0 + HU051MR U4442 dB(A); 60 / 58; 34 dB(A); 38 / 36
LG HN1600MC NK1 + HU123MRB U3061 / 60; 44 dB(A); 39 / 38; 36 dB(A)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 42; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 60 / 58; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 34; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 38 / 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Check the exact configuration and source conditions for your use.

Show 24 more verified differences

Manufacturer dimensions and configuration basis

In Visual facts
LG HN0913T NK0 + HU051MR U44600 × 1,750 × 660 (Indoor unit (W × H × D) (mm)); 950 × 834 × 330 (Outdoor unit (W × H × D) (mm))
LG HN1600MC NK1 + HU123MRB U30950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

A size or weight trade-off; it does not establish the better product.

Missing or non-comparable evidence (19)

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))

LG HN0913T NK0 + HU051MR U44Ø 15.88 (5/8)
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)

LG HN0913T NK0 + HU051MR U445 / 50
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)

LG HN0913T NK0 + HU051MR U4430
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))

LG HN0913T NK0 + HU051MR U44Ø 9.52 (3/8)
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)

LG HN0913T NK0 + HU051MR U4440
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)

LG HN0913T NK0 + HU051MR U4410
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for DHW (inch)

LG HN0913T NK0 + HU051MR U44Female G1"
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)

LG HN0913T NK0 + HU051MR U44Female G1"
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)

LG HN0913T NK0 + HU051MR U44Not verified
LG HN1600MC NK1 + HU123MRB U30Male PT 1"
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded for this side.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)

LG HN0913T NK0 + HU051MR U44Not verified
LG HN1600MC NK1 + HU123MRB U30Male PT 1"
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded for this side.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for DHW (inch)

LG HN0913T NK0 + HU051MR U44Female G1"
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)

LG HN0913T NK0 + HU051MR U44Female G1"
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)

LG HN0913T NK0 + HU051MR U44Female G1"
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)

LG HN0913T NK0 + HU051MR U44Not verified
LG HN1600MC NK1 + HU123MRB U30Male PT 1"
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded for this side.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)

LG HN0913T NK0 + HU051MR U44Not verified
LG HN1600MC NK1 + HU123MRB U30Male PT 1"
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded for this side.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — COPDHW, average climate

LG HN0913T NK0 + HU051MR U443.15
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — Declared load profile, average climate

LG HN0913T NK0 + HU051MR U44L
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate

LG HN0913T NK0 + HU051MR U44A+
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate

LG HN0913T NK0 + HU051MR U44133
LG HN1600MC NK1 + HU123MRB U30Not verified
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

11 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HN0913T NK0 + HU051MR U44

What it brings

  • The official LG UK page identifies manufacturer model HN0913T NK0 + HU051MR U44.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HN1600MC NK1 + HU123MRB U30

What it brings

  • The official LG UK page identifies manufacturer model HN1600MC NK1 + HU123MRB U30.

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
60 of 60 specifications Sources in each row
Source-backed specifications for LG HN0913T NK0 + HU051MR U44 and LG HN1600MC NK1 + HU123MRB U30
SpecificationLG HN0913T NK0 + HU051MR U44LG HN1600MC NK1 + HU123MRB U30
Manufacturer heating capacities at separate operating pointsDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 3.30; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 5.50; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
3.30 kW (A+2/W+35); 5.50 kW (A+7/W+35); 5.50 kW (A+7/W+55)12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating pointsDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 5.50; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 12.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5.50 kW (A+35/W+18); 5.50 kW (A+35/W+7)12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Manufacturer efficiency declarations and source methodsDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.52; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.90; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.60; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2.80; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 183 / 126; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.65 / 3.23; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate: 133; WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate: A+. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 181 / 137; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.60 / 3.50; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 5.04; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.65; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.90; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.75; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 2,70. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
COP 3.52 (A+2/W+35); COP 4.90 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.60 (A+35/W+18); EER 2.80 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 183 / 126; SCOP (35℃ / 55℃) 4.65 / 3.23; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 133; Water heating eff. class, average climate A+Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 181 / 137; SCOP (35℃ / 55℃) 4.60 / 3.50; COP 5.04 (A+7/W+35); COP 3.65 (A+2/W+35); COP 2.90 (A+7/W+55); EER 4.75 (A+35/W+18); EER 2,70 (A+35/W+7)
NOMINAL CAPACITY AND COP (A+2/W+35) — COPDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
3.523.65
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
3.3011.00
NOMINAL CAPACITY AND COP (A+7/W+35) — COPDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
4.905.04
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5.5012.00
NOMINAL CAPACITY AND COP (A+7/W+55) — COPDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
2.702.90
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5.5011.00
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5.5012.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EERDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
4.604.75
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5.5012.00
NOMINAL CAPACITY AND EER (A+35/W+7) — EERDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
2.802,70
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
183 / 126181 / 137
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
4.65 / 3.234.60 / 3.50
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
A+++/A++A+++/A++
WATER HEATING EFFICIENCY DATA — Water heating efficiency (ηWH), average climate
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

133Not provided
WATER HEATING EFFICIENCY DATA — COPDHW, average climate
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

3.15Not provided
WATER HEATING EFFICIENCY DATA — Declared load profile, average climate
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

LNot provided
WATER HEATING EFFICIENCY DATA — Water heating eff. class, average climate
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

A+Not provided
Manufacturer refrigerant type
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
R32R32
REFRIGERANT — GWP
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
675675
REFRIGERANT — Precharged amount (g)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
1,5002,100
REFRIGERANT — Type
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
R32R32
Manufacturer electrical supply requirementsDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 380-415, 3, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
220-240, 1, 50380-415, 3, 50
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
220-240, 1, 50380-415, 3, 50
Exact manufacturer unit purposeDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
R32 Split 5/7/9 kW IWT, 1Ø, 5kW HN0913T NK0 + HU051MR U44R32 Hydrosplit Hydro Box, 3Ø, 12kW HN1600MC NK1 + HU123MRB U30
Manufacturer dimensions and configuration basisDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm). Manufacturer section: DIMENSIONS. Source field: Indoor unit (W × H × D) (mm).

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
600 × 1,750 × 660 (Indoor unit (W × H × D) (mm)); 950 × 834 × 330 (Outdoor unit (W × H × D) (mm))950 × 1,380 × 330 (Outdoor unit (W × H × D) (mm)); 490 × 850 × 315 (Indoor unit (W × H × D) (mm))
DIMENSIONS — Indoor unit (W × H × D) (mm)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
600 × 1,750 × 660490 × 850 × 315
DIMENSIONS — Outdoor unit (W × H × D) (mm)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
950 × 834 × 330950 × 1,380 × 330
EXTERIOR — Indoor unit (Color / RAL code)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
White / RAL 9016Noble white / RAL 9016
EXTERIOR — Outdoor unit (Color / RAL code)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
Warm gray / RAL 7044Warm gray / RAL 7044
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Gas (mm (inch))
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Ø 15.88 (5/8)Not provided
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Length standard / Max. (m)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

5 / 50Not provided
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Level difference Max. (m)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

30Not provided
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Liquid (mm (inch))
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Ø 9.52 (3/8)Not provided
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Mass of additional ref. charge (g/m)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

40Not provided
PIPING CONNECTIONS (REF./OUTDOOR UNIT) — Max. length without additional charge (m)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

10Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for space heating (inch)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Female G1"Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet diameter for DHW (inch)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Female G1"Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for DHW (inch)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Female G1"Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Outlet diameter for space heating (inch)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Female G1"Not provided
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Recirculation (inch)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

No source recorded.

Female G1"Not provided
WEIGHT — Indoor unit (Empty) (kg)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
118.030.5
WEIGHT — Outdoor unit (Empty) (kg)Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
60.091.7
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
Not providedMale PT 1"
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
Not providedMale PT 1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for ODU connection (inch)
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
Not providedMale PT 1"
PIPING CONNECTIONS (WATER/INDOOR UNIT) — Inlet/outlet diameter for space heating (inch)
Sources
LG HN0913T NK0 + HU051MR U44

No source recorded.

LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
Not providedMale PT 1"
Manufacturer operating ranges and conditions
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 35-25 ~ 35; 5 ~ 48; 15 ~ 65; 5 ~ 27; 15 ~ 80
Manufacturer sound declarations and measurement methodsDifferent
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 42; SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 60 / 58; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 34; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 38 / 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 60; SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A)): 44; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 38; SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A)): 36. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
42 dB(A); 60 / 58; 34 dB(A); 38 / 3661 / 60; 44 dB(A); 39 / 38; 36 dB(A)
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
15 ~ 8015 ~ 80
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
15 ~ 6515 ~ 65
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
-25 ~ 35-25 ~ 35
SOUND POWER LEVEL (INDOOR UNIT) — Rated (dB(A))Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
4244
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
60 / 5861 / 60
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) — Rated (dB(A))Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
3436
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))Different
Sources
LG HN0913T NK0 + HU051MR U44

Manufacturer specification

LG UK — HN0913T NK0 + HU051MR U44 manufacturer specifications
LG HN1600MC NK1 + HU123MRB U30

Manufacturer specification

LG UK — HN1600MC NK1 + HU123MRB U30 manufacturer specifications
38 / 3639 / 38
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30

LG HN1600MC NK1 + HU121MRB U30

Exact manufacturer unit purpose
R32 Hydrosplit Hydro Box, 1Ø, 12kW HN1600MC NK1 + HU121MRB U30
Manufacturer heating capacities at separate operating points
12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 1Ø, 12kW HM121MR U34

LG HM121MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 12kW HM121MR U34
Manufacturer heating capacities at separate operating points
12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 3Ø, 12kW HM123MR U34

LG HM123MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 3Ø, 12kW HM123MR U34
Manufacturer heating capacities at separate operating points
12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Split 5/7/9 kW Hydro Box, 1Ø, 5kW HN091MR NK5 + HU051MR U44

LG HN091MR NK5 + HU051MR U44

Exact manufacturer unit purpose
R32 Split 5/7/9 kW Hydro Box, 1Ø, 5kW HN091MR NK5 + HU051MR U44
Manufacturer heating capacities at separate operating points
5.50 kW (A+7/W+35); 3.30 kW (A+2/W+35); 5.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
5.50 kW (A+35/W+18); 5.50 kW (A+35/W+7)
Prices & product profile

Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.