Skip to comparison
versus.deals
Menu
Browse versus.deals
HEAT PUMPS · YOUR NEXT FACE-OFF

LG HM161MRS vs LG HM071MR U44

Real specs. Clear sources.Exact models · UK & US buying links

Compared products

YOUR FIRST CHOICE

LG HM161MRS

UK manufacturer configuration · HM161MRS

LG Air to Water Heat Pumps  HM161MRS UB40, front view of a black outdoor unit featuring a grey wavy grille.
Exact model & source notes

LG HM161MRS in the exact manufacturer-listed UK configuration.

Specifications checked 20 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications
WHAT DIFFERS
Manufacturer sound declarations and measurement methods61 / 57; 39 / 3557 / 55; 49 / 47; 35 / 33
NOMINAL CAPACITY AND COP (A+2/W+35) — COP3.503.55
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)13.805.60
3 of 16 verified differences, in the order listed below. Not a rating.
See the 16 verified differences
THE CONTENDER

LG HM071MR U44

UK manufacturer configuration · HM071MR U44

Front view of R32 Monobloc S, 1Ø, 7kW HM071MR U44
Exact model & source notes

LG HM071MR U44 in the exact manufacturer-listed UK configuration.

Specifications checked 19 Oct 2026.

Amazon links open search results. Check the exact variant, current price and availability with the retailer.

Manufacturer specifications

HM161MRS UK & US retailers

UK & US price history: no verified listing yet

HM071MR U44 UK & US retailers

UK & US price history: no verified listing yet

Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.

THE DIFFERENCES, MADE VISIBLE

Visual facts

Differences first. Select a topic for its graphic, sources and conditions.

How to read this comparison
  • Manufacturer facts for the exact models shown. Not a quality rating or a test result.
  • “Different” means the known values differ, not that one is better.
  • Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE7 topics
SELECTED TOPIC
01 / 07

Exact manufacturer unit purpose

Check the exact configuration and source conditions for your use.

LG HM161MRSR32 Monobloc S II, 1Ø, 16kW

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG HM071MR U44R32 Monobloc S, 1Ø, 7kW HM071MR U44

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

Explore the full specifications

Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.

WHAT CHANGES BETWEEN THEM?

Key differences

Full specifications ↓

16 verified differences, most decision-relevant first. 7 are also drawn in Visual facts above. Missing information stays separate.

Exact manufacturer unit purpose

In Visual facts
LG HM161MRSR32 Monobloc S II, 1Ø, 16kW
LG HM071MR U44R32 Monobloc S, 1Ø, 7kW HM071MR U44
Sources
LG HM161MRS

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM071MR U44 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer heating capacities at separate operating points

In Visual facts
LG HM161MRS16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)
LG HM071MR U445.60 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 5.60; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 7.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer cooling capacities at separate operating points

In Visual facts
LG HM161MRS16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)
LG HM071MR U447.00 kW (A+35/W+18); 7.00 kW (A+35/W+7)
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 7.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 7.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer efficiency declarations and source methods

In Visual facts
LG HM161MRSSCOP (35℃ / 55℃) 4.53 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; COP 4.70 (A+7/W+35); COP 3.50 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.60 (A+35/W+18); EER 3.00 (A+35/W+7)
LG HM071MR U44COP 3.55 (A+2/W+35); COP 4.70 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.70 (A+35/W+18); EER 3.20 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 176 / 125; SCOP (35℃ / 55℃) 4.48 / 3.20; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 176 / 125; SCOP (35℃ / 55℃) 4.48 / 3.20; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.53 / 3.45; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.50; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.60; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.55; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.70; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications

Check the exact configuration and source conditions for your use.

Manufacturer sound declarations and measurement methods

In Visual facts
LG HM161MRS61 / 57; 39 / 35
LG HM071MR U4457 / 55; 49 / 47; 35 / 33
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 57 / 55; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 49 / 47; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 35 / 33. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications

Check the exact configuration and source conditions for your use.

Show 10 more verified differences
Missing or non-comparable evidence (22)

Manufacturer dimensions and configuration basis

LG HM161MRS1,320 x 1,019 x 520 mm
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · Manufacturer specification · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

DIMENSIONS — Outdoor unit (W × H × D) (mm)

LG HM161MRS1,320 x 1,019 x 520
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — Color

LG HM161MRSNot verified
LG HM071MR U44Warm gray
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — Color of outdoor unit chassis (Color / RAL code)

LG HM161MRSDawn gray / RAL 7037
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — Color of outdoor unit front grille (Color / RAL code)

LG HM161MRSDark dawn gray / RAL 7012
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

EXTERIOR — RAL code

LG HM161MRSNot verified
LG HM071MR U44RAL 7044
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER) — Inlet diameter (inch)

LG HM161MRSNot verified
LG HM071MR U44Male PT 1"
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)

LG HM161MRSMale PT 1"
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)

LG HM161MRSMale PT 1"
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

PIPING CONNECTIONS (WATER) — Outlet diameter (inch)

LG HM161MRSNot verified
LG HM071MR U44Male PT 1"
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz)

LG HM161MRS220 ~ 240, 1, 50
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)

LG HM161MRSNot verified
LG HM071MR U44220-240, 1, 50
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))

LG HM161MRS61 / 57
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND POWER LEVEL — Rated / low noise mode (dB(A))

LG HM161MRSNot verified
LG HM071MR U4457 / 55
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A))

LG HM161MRSNot verified
LG HM071MR U4449 / 47
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A))

LG HM161MRSNot verified
LG HM071MR U4435 / 33
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))

LG HM161MRS39 / 35
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

WEIGHT — Outdoor unit (Empty) (kg)

LG HM161MRS117.0
LG HM071MR U44Not verified
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded for this side.

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)

LG HM161MRSNot verified
LG HM071MR U44176 / 125
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃)

LG HM161MRSNot verified
LG HM071MR U444.48 / 3.20
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃)

LG HM161MRSNot verified
LG HM071MR U44A+++/A++
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃)

LG HM161MRSNot verified
LG HM071MR U44176 / 125
Sources
LG HM161MRS

No source recorded for this side.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications

Evidence is missing or conflicting on at least one side. This is not a verified difference.

12 shared fields have the same recorded value.

WHAT EACH CHOICE ASKS OF YOU

What it brings and what to check

LG HM161MRS

What it brings

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.

LG HM071MR U44

What it brings

What to check

  • Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
COMPARE THE DETAILS

Full specifications

How we verify
50 of 50 specifications Sources in each row
Source-backed specifications for LG HM161MRS and LG HM071MR U44
SpecificationLG HM161MRSLG HM071MR U44
Manufacturer heating capacities at separate operating pointsDifferent
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 5.60; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 7.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
16.00 kW (A+7/W+35); 13.80 kW (A+2/W+35); 12.00 kW (A+7/W+55)5.60 kW (A+2/W+35); 7.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating pointsDifferent
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 7.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 7.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)7.00 kW (A+35/W+18); 7.00 kW (A+35/W+7)
Manufacturer efficiency declarations and source methodsDifferent
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.53 / 3.45; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.50; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.60; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.55; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.70; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
SCOP (35℃ / 55℃) 4.53 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; COP 4.70 (A+7/W+35); COP 3.50 (A+2/W+35); COP 2.80 (A+7/W+55); EER 4.60 (A+35/W+18); EER 3.00 (A+35/W+7)COP 3.55 (A+2/W+35); COP 4.70 (A+7/W+35); COP 2.70 (A+7/W+55); EER 4.70 (A+35/W+18); EER 3.20 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 176 / 125; SCOP (35℃ / 55℃) 4.48 / 3.20; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 176 / 125; SCOP (35℃ / 55℃) 4.48 / 3.20; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++
SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
4.53 / 3.454.48 / 3.20
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
A+++/A++A+++/A++
NOMINAL CAPACITY AND COP (A+7/W+35) — COP
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
4.704.70
NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
16.007.00
NOMINAL CAPACITY AND COP (A+2/W+35) — COPDifferent
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
3.503.55
NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
13.805.60
NOMINAL CAPACITY AND COP (A+7/W+55) — COPDifferent
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
2.802.70
NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
12.005.50
NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
16.007.00
NOMINAL CAPACITY AND EER (A+35/W+18) — EERDifferent
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
4.604.70
NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
15.007.00
NOMINAL CAPACITY AND EER (A+35/W+7) — EERDifferent
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
3.003.20
SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided176 / 125
SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided4.48 / 3.20
SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not providedA+++/A++
SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided176 / 125
Manufacturer refrigerant type
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
R32R32
REFRIGERANT — Type
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
R32R32
REFRIGERANT — GWP
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
675675
REFRIGERANT — Precharged amount (g)Different
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
1,6001,400
Manufacturer electrical supply requirements
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 220 ~ 240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
220 ~ 240, 1, 50220-240, 1, 50
POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

220 ~ 240, 1, 50Not provided
POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided220-240, 1, 50
Exact manufacturer unit purposeDifferent
Sources
LG HM161MRS

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — HM071MR U44 manufacturer specifications
R32 Monobloc S II, 1Ø, 16kWR32 Monobloc S, 1Ø, 7kW HM071MR U44
Manufacturer dimensions and configuration basis
Sources
LG HM161MRS

Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · Manufacturer specification · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.

LG UK — HM071MR U44 manufacturer specifications
1,320 x 1,019 x 520 mmNot listed by the manufacturer
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Inlet diameter (inch)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

Male PT 1"Not provided
PIPING CONNECTIONS (WATER/OUTDOOR UNIT) — Outlet diameter (inch)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

Male PT 1"Not provided
DIMENSIONS — Outdoor unit (W × H × D) (mm)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

1,320 x 1,019 x 520Not provided
WEIGHT — Outdoor unit (Empty) (kg)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

117.0Not provided
EXTERIOR — Color of outdoor unit chassis (Color / RAL code)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

Dawn gray / RAL 7037Not provided
EXTERIOR — Color of outdoor unit front grille (Color / RAL code)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

Dark dawn gray / RAL 7012Not provided
EXTERIOR — Color
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not providedWarm gray
EXTERIOR — RAL code
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not providedRAL 7044
PIPING CONNECTIONS (WATER) — Inlet diameter (inch)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not providedMale PT 1"
PIPING CONNECTIONS (WATER) — Outlet diameter (inch)
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not providedMale PT 1"
Manufacturer operating ranges and conditions
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
5 ~ 48; -25 ~ 35; 5 ~ 27; 15 ~ 80; 15 ~ 655 ~ 27; 15 ~ 80; 15 ~ 65; 5 ~ 48; -25 ~ 35
Manufacturer sound declarations and measurement methodsDifferent
Sources
LG HM161MRS

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 57 / 55; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 49 / 47; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 35 / 33. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — HM071MR U44 manufacturer specifications
61 / 57; 39 / 3557 / 55; 49 / 47; 35 / 33
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
5 ~ 485 ~ 48
OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
-25 ~ 35-25 ~ 35
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
5 ~ 275 ~ 27
OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
15 ~ 8015 ~ 80
OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃)
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
15 ~ 6515 ~ 65
SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A))
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

61 / 57Not provided
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM161MRS

Manufacturer specification

LG UK — HM161MRS manufacturer specifications
LG HM071MR U44

No source recorded.

39 / 35Not provided
SOUND POWER LEVEL — Rated / low noise mode (dB(A))
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided57 / 55
SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided49 / 47
SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A))
Sources
LG HM161MRS

No source recorded.

LG HM071MR U44

Manufacturer specification

LG UK — HM071MR U44 manufacturer specifications
Not provided35 / 33
FIND YOUR CONTENDERS

More products

Closest heat pumps to this pair by shared key specifications. Not a popularity ranking.

See all 43 heat pumps
Front view of R32 Monobloc S II, 3Ø, 16kW HM163MRS UB40

LG HM163MRS UB40

Exact manufacturer unit purpose
R32 Monobloc S II, 3Ø, 16kW
Manufacturer heating capacities at separate operating points
13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)
Prices & product profile
LG Air to Water Heat Pumps  HM141MRS UB40, front view of a black outdoor unit featuring a grey wavy grille.

LG HM141MRS

Exact manufacturer unit purpose
R32 Monobloc S II, 1Ø, 14kW
Manufacturer heating capacities at separate operating points
14.00 kW (A+7/W+35); 12.00 kW (A+2/W+35); 11.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
14.00 kW (A+35/W+18); 14.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 1Ø, 16kW HM161MR U34

LG HM161MR U34

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 16kW HM161MR U34
Manufacturer heating capacities at separate operating points
13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7)
Prices & product profile
Front view of R32 Monobloc S, 1Ø, 9kW HM091MR U44

LG HM091MR U44

Exact manufacturer unit purpose
R32 Monobloc S, 1Ø, 9kW HM091MR U44
Manufacturer heating capacities at separate operating points
6.80 kW (A+2/W+35); 9.00 kW (A+7/W+35); 5.50 kW (A+7/W+55)
Manufacturer cooling capacities at separate operating points
9.00 kW (A+35/W+18); 9.00 kW (A+35/W+7)
Prices & product profile