Search links open retailer results, not a matched listing; eBay listings are checked daily. As an Amazon Associate I earn from qualifying purchases. As an eBay Partner, we may be compensated if you make a purchase.
THE DIFFERENCES, MADE VISIBLE
Visual facts
Differences first. Select a topic for its graphic, sources and conditions.
How to read this comparison
Manufacturer facts for the exact models shown. Not a quality rating or a test result.
“Different” means the known values differ, not that one is better.
Missing or conflicting evidence is marked and never counts as a difference. Source chips hold each fact’s sources and conditions.
SPECIFICATIONS SIDE BY SIDE7 topics
SELECTED TOPIC
01 / 07
Exact manufacturer unit purpose
Check the exact configuration and source conditions for your use.
LG HM161MRSR32 Monobloc S II, 1Ø, 16kW
Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
Check the exact configuration. Manufacturer specifications describe the listed variant. Confirm compatibility and the seller’s exact model before buying; no overall winner is inferred from incomplete evidence.
Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 5.60; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 7.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
LG HM161MRS16.00 kW (A+35/W+18); 15.00 kW (A+35/W+7)
LG HM071MR U447.00 kW (A+35/W+18); 7.00 kW (A+35/W+7)
Sources
LG HM161MRS
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 7.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 7.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.53 / 3.45; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.50; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.60; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.55; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.70; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 57 / 55; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 49 / 47; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 35 / 33. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Check the exact configuration and source conditions for your use.
Missing or non-comparable evidence (22)
Manufacturer dimensions and configuration basis
LG HM161MRS1,320 x 1,019 x 520 mm
LG HM071MR U44Not verified
Sources
LG HM161MRS
Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).
The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · Manufacturer specification · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.
Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.
Source-backed specifications for LG HM161MRS and LG HM071MR U44
Specification
LG HM161MRS
LG HM071MR U44
Manufacturer heating capacities at separate operating pointsDifferentSources
LG HM161MRS
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 16.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 13.80; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 12.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 5.60; NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 7.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 5.50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer cooling capacities at separate operating pointsDifferentSources
LG HM161MRS
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 16.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 15.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND EER (A+35/W+18) — Cooling capacity (kW): 7.00; NOMINAL CAPACITY AND EER (A+35/W+7) — Cooling capacity (kW): 7.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer efficiency declarations and source methodsDifferentSources
LG HM161MRS
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.53 / 3.45; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.50; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.80; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.60; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+2/W+35) — COP: 3.55; NOMINAL CAPACITY AND COP (A+7/W+35) — COP: 4.70; NOMINAL CAPACITY AND COP (A+7/W+55) — COP: 2.70; NOMINAL CAPACITY AND EER (A+35/W+18) — EER: 4.70; NOMINAL CAPACITY AND EER (A+35/W+7) — EER: 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating efficiency (ηS) (35℃ / 55℃): 176 / 125; SEASONAL EFFICIENCY DATA (HEATING) — SCOP (35℃ / 55℃): 4.48 / 3.20; SEASONAL EFFICIENCY DATA (HEATING) — Seasonal space heating eff. class (35℃ / 55℃): A+++/A++. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency for outdoor unit (V, Ø, Hz): 220 ~ 240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Air to Water Heat Pump. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
Manufacturer specification · Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
Manufacturer dimensions and configuration basisSources
LG HM161MRS
Manufacturer specification · Original units, axes and stand/component/handle basis retained. No packaging dimension or unstated unit is substituted. Manufacturer section: DIMENSIONS. Source field: Outdoor unit (W × H × D) (mm).
The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed. · Manufacturer specification · The manufacturer does not supply complete, unambiguous unit-labelled dimensions for the relevant product/components. Original declarations: none. Missing units or malformed component values are not guessed.
Manufacturer operating ranges and conditionsSources
LG HM161MRS
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. OPERATION RANGE (LEAVING WATER TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 27; OPERATION RANGE (LEAVING WATER TEMPERATURE) — DHW (Min. ~ Max.) (℃): 15 ~ 80; OPERATION RANGE (LEAVING WATER TEMPERATURE) — Heating (Min. ~ Max.) (℃): 15 ~ 65; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Cooling (Min. ~ Max.) (℃): 5 ~ 48; OPERATION RANGE (OUTDOOR AIR TEMPERATURE) — Heating & DHW (Min. ~ Max.) (℃): -25 ~ 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer sound declarations and measurement methodsDifferentSources
LG HM161MRS
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL (OUTDOOR UNIT) — Rated / low noise mode (dB(A)): 61 / 57; SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) — Rated / low noise mode (dB(A)): 39 / 35. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Manufacturer specification · Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. SOUND POWER LEVEL — Rated / low noise mode (dB(A)): 57 / 55; SOUND PRESSURE LEVEL AT 1M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 49 / 47; SOUND PRESSURE LEVEL AT 5M (CONVERT USING SWL) — Rated / low noise mode (dB(A)): 35 / 33. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
Each record represents an explicitly checked model and configuration. Original import: 5 Sept 2026; this is not its verification date. This is not a list of current offers or a popularity ranking.