Air conditioning & HVAC units · 1/5 in this check (kept in the link)

Share or save

The air conditioning & hvac unit you are considering

LG ARUM120LTE6

UK manufacturer configuration · ARUM120LTE6
Manufacturer unit type and installation role
MULTI V i, Outdoor Unit, 12HP, R410A
Heating-capacity declarations and operating conditions
33.6 kW; 37.8 kW; 129000
Cooling-capacity declarations and operating conditions
33.6 kW
Electrical supply requirements
50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Your shortlisted products

Your prioritiesCategory, search, shopping market, budget and must-haves

Alternatives to LG ARUM120LTE6

Select must-haves to check which products meet your requirements.

Closest to the LG ARUM120LTE6 by stated key specifications first. Closeness is not a ranking; each card lists what differs.

Front view of MULTI V i, Outdoor Unit, 8HP, R410A ARUM080LTE6
UK model

LG ARUM080LTE6

Compared with · LG ARUM120LTE6

  • Manufacturer unit type and installation roleMULTI V i, Outdoor Unit, 12HP, R410A → MULTI V i, Outdoor Unit, 8HP, R410A
  • Heating-capacity declarations and operating conditions33.6 kW; 37.8 kW; 129000 → 22.4 kW; 25.2 kW; 86000
  • Cooling-capacity declarations and operating conditions33.6 kW → 22.4 kW
  • Efficiency declarations, methods and operating conditionsEER(Rated) (W/W) 2.88; COP(Rated) (W/W) 4.32; SEER (Wh/Wh) 7.94; SCOP (Wh/Wh) 4.99 → EER(Rated) (W/W) 3.67; COP(Rated) (W/W) 4.34; SEER (Wh/Wh) 8.28; SCOP (Wh/Wh) 4.45
  • Sound declarations and measurement basis59 / 60; 80 / 82 → 57 / 58; 78 / 78

Same: Electrical supply requirements 50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Compare side by side
View details

Full comparison vs LG ARUM100LTE6

More details & evidence

Exact model: UK manufacturer configuration · ARUM080LTE6

Sources: 51 of 52 specifications cited.

Evidence · Some facts need verification

51/52 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeMULTI V i, Outdoor Unit, 8HP, R410A
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — ARUM080LTE6 manufacturer specifications
Manufacturer heating capacities at separate operating points22.4 kW; 25.2 kW; 86000
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 22.4; HEATING CAPACITY — Max (kW): 25.2; HEATING CAPACITY — Max (Btu/h): 86000. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM080LTE6 manufacturer specifications
Manufacturer cooling capacities at separate operating points22.4 kW
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 22.4. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM080LTE6 manufacturer specifications
Manufacturer electrical supply requirements50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 60 Hz 380 V 3N~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM080LTE6 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of MULTI V i, Outdoor Unit, 10HP, R410A ARUM100LTE6
UK model

LG ARUM100LTE6

Compared with · LG ARUM120LTE6

  • Manufacturer unit type and installation roleMULTI V i, Outdoor Unit, 12HP, R410A → MULTI V i, Outdoor Unit, 10HP, R410A
  • Heating-capacity declarations and operating conditions33.6 kW; 37.8 kW; 129000 → 28 kW; 31.5 kW; 107500
  • Cooling-capacity declarations and operating conditions33.6 kW → 28 kW
  • Efficiency declarations, methods and operating conditionsEER(Rated) (W/W) 2.88; COP(Rated) (W/W) 4.32; SEER (Wh/Wh) 7.94; SCOP (Wh/Wh) 4.99 → EER(Rated) (W/W) 3.36; COP(Rated) (W/W) 4.50; SEER (Wh/Wh) 8.11; SCOP (Wh/Wh) 4.52
  • Sound declarations and measurement basis59 / 60; 80 / 82 → 57.5 / 58.5; 79 / 79

Same: Electrical supply requirements 50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Compare side by side
View details

Full comparison vs LG ARUM080LTE6

More details & evidence

Exact model: UK manufacturer configuration · ARUM100LTE6

Sources: 51 of 52 specifications cited.

Evidence · Some facts need verification

51/52 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeMULTI V i, Outdoor Unit, 10HP, R410A
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — ARUM100LTE6 manufacturer specifications
Manufacturer heating capacities at separate operating points28 kW; 31.5 kW; 107500
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 28; HEATING CAPACITY — Max (kW): 31.5; HEATING CAPACITY — Max (Btu/h): 107500. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM100LTE6 manufacturer specifications
Manufacturer cooling capacities at separate operating points28 kW
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 28. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM100LTE6 manufacturer specifications
Manufacturer electrical supply requirements50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 60 Hz 380 V 3N~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM100LTE6 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of MULTI V i, Outdoor Unit, 14HP, R410A ARUM140LTE6
UK model

LG ARUM140LTE6

Compared with · LG ARUM120LTE6

  • Manufacturer unit type and installation roleMULTI V i, Outdoor Unit, 12HP, R410A → MULTI V i, Outdoor Unit, 14HP, R410A
  • Heating-capacity declarations and operating conditions33.6 kW; 37.8 kW; 129000 → 39.2 kW; 44.1 kW; 150500
  • Cooling-capacity declarations and operating conditions33.6 kW → 39.2 kW
  • Efficiency declarations, methods and operating conditionsEER(Rated) (W/W) 2.88; COP(Rated) (W/W) 4.32; SEER (Wh/Wh) 7.94; SCOP (Wh/Wh) 4.99 → EER(Rated) (W/W) 3.30; COP(Rated) (W/W) 4.65; SEER (Wh/Wh) 8.55; SCOP (Wh/Wh) 5.17
  • Sound declarations and measurement basis59 / 60; 80 / 82 → 60 / 61; 81 / 81
1 more difference
  • Dimensions and component basis930 x 1745 x 760 mm → 1240 x 1745 x 760 mm

Same: Electrical supply requirements 50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Compare side by side
View details

Full comparison vs LG ARUM080LTE6

More details & evidence

Exact model: UK manufacturer configuration · ARUM140LTE6

Sources: 51 of 52 specifications cited.

Evidence · Some facts need verification

51/52 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeMULTI V i, Outdoor Unit, 14HP, R410A
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — ARUM140LTE6 manufacturer specifications
Manufacturer heating capacities at separate operating points39.2 kW; 44.1 kW; 150500
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 39.2; HEATING CAPACITY — Max (kW): 44.1; HEATING CAPACITY — Max (Btu/h): 150500. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM140LTE6 manufacturer specifications
Manufacturer cooling capacities at separate operating points39.2 kW
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 39.2. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM140LTE6 manufacturer specifications
Manufacturer electrical supply requirements50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 60 Hz 380 V 3N~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM140LTE6 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of MULTI V i, Outdoor Unit, 16HP, R410A ARUM160LTE6
UK model

LG ARUM160LTE6

Compared with · LG ARUM120LTE6

  • Manufacturer unit type and installation roleMULTI V i, Outdoor Unit, 12HP, R410A → MULTI V i, Outdoor Unit, 16HP, R410A
  • Heating-capacity declarations and operating conditions33.6 kW; 37.8 kW; 129000 → 44.8 kW; 50.4 kW; 172000
  • Cooling-capacity declarations and operating conditions33.6 kW → 44.8 kW
  • Efficiency declarations, methods and operating conditionsEER(Rated) (W/W) 2.88; COP(Rated) (W/W) 4.32; SEER (Wh/Wh) 7.94; SCOP (Wh/Wh) 4.99 → EER(Rated) (W/W) 2.90; COP(Rated) (W/W) 4.44; SEER (Wh/Wh) 7.97; SCOP (Wh/Wh) 5.46
  • Sound declarations and measurement basis59 / 60; 80 / 82 → 60.5 / 61.5; 85 / 85
1 more difference
  • Dimensions and component basis930 x 1745 x 760 mm → 1240 x 1745 x 760 mm

Same: Electrical supply requirements 50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Compare side by side
View details

Full comparison vs LG ARUM080LTE6

More details & evidence

Exact model: UK manufacturer configuration · ARUM160LTE6

Sources: 51 of 52 specifications cited.

Evidence · Some facts need verification

51/52 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeMULTI V i, Outdoor Unit, 16HP, R410A
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — ARUM160LTE6 manufacturer specifications
Manufacturer heating capacities at separate operating points44.8 kW; 50.4 kW; 172000
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 44.8; HEATING CAPACITY — Max (kW): 50.4; HEATING CAPACITY — Max (Btu/h): 172000. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM160LTE6 manufacturer specifications
Manufacturer cooling capacities at separate operating points44.8 kW
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 44.8. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM160LTE6 manufacturer specifications
Manufacturer electrical supply requirements50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 60 Hz 380 V 3N~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM160LTE6 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of MULTI V i, Outdoor Unit, 18HP, R410A ARUM180LTE6
UK model

LG ARUM180LTE6

Compared with · LG ARUM120LTE6

  • Manufacturer unit type and installation roleMULTI V i, Outdoor Unit, 12HP, R410A → MULTI V i, Outdoor Unit, 18HP, R410A
  • Heating-capacity declarations and operating conditions33.6 kW; 37.8 kW; 129000 → 50.4 kW; 56.7 kW; 193500
  • Cooling-capacity declarations and operating conditions33.6 kW → 50.4 kW
  • Efficiency declarations, methods and operating conditionsEER(Rated) (W/W) 2.88; COP(Rated) (W/W) 4.32; SEER (Wh/Wh) 7.94; SCOP (Wh/Wh) 4.99 → EER(Rated) (W/W) 3.50; COP(Rated) (W/W) 4.76; SEER (Wh/Wh) 8.65; SCOP (Wh/Wh) 4.81
  • Sound declarations and measurement basis59 / 60; 80 / 82 → 61 / 62; 85 / 86
1 more difference
  • Dimensions and component basis930 x 1745 x 760 mm → 1240 x 1745 x 760 mm

Same: Electrical supply requirements 50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Compare side by side
View details

Full comparison vs LG ARUM080LTE6

More details & evidence

Exact model: UK manufacturer configuration · ARUM180LTE6

Sources: 51 of 52 specifications cited.

Evidence · Some facts need verification

51/52 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeMULTI V i, Outdoor Unit, 18HP, R410A
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — ARUM180LTE6 manufacturer specifications
Manufacturer heating capacities at separate operating points50.4 kW; 56.7 kW; 193500
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 50.4; HEATING CAPACITY — Max (kW): 56.7; HEATING CAPACITY — Max (Btu/h): 193500. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM180LTE6 manufacturer specifications
Manufacturer cooling capacities at separate operating points50.4 kW
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 50.4. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM180LTE6 manufacturer specifications
Manufacturer electrical supply requirements50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 60 Hz 380 V 3N~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM180LTE6 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →
Front view of MULTI V i, Outdoor Unit, 20HP, R410A ARUM200LTE6
UK model

LG ARUM200LTE6

Compared with · LG ARUM120LTE6

  • Manufacturer unit type and installation roleMULTI V i, Outdoor Unit, 12HP, R410A → MULTI V i, Outdoor Unit, 20HP, R410A
  • Heating-capacity declarations and operating conditions33.6 kW; 37.8 kW; 129000 → 56 kW; 63 kW; 215000
  • Cooling-capacity declarations and operating conditions33.6 kW → 56 kW
  • Efficiency declarations, methods and operating conditionsEER(Rated) (W/W) 2.88; COP(Rated) (W/W) 4.32; SEER (Wh/Wh) 7.94; SCOP (Wh/Wh) 4.99 → EER(Rated) (W/W) 3.19; COP(Rated) (W/W) 4.43; SEER (Wh/Wh) 8.42; SCOP (Wh/Wh) 5.13
  • Sound declarations and measurement basis59 / 60; 80 / 82 → 62 / 63.5; 86 / 89
1 more difference
  • Dimensions and component basis930 x 1745 x 760 mm → 1240 x 1745 x 760 mm

Same: Electrical supply requirements 50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~

Compare side by side
View details

Full comparison vs LG ARUM080LTE6

More details & evidence

Exact model: UK manufacturer configuration · ARUM200LTE6

Sources: 51 of 52 specifications cited.

Evidence · Some facts need verification

51/52 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.

Manufacturer facts
51
Calculated from sources
0
Independent measurements
Not available
Owner evidence
Not available
Conflicting facts
None recorded
View the manufacturer source

UK exact model

Market details

UK specification. UK availability not verified.

The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.

Check the manufacturer source

We have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.

Before you choose

Key specification sources
Exact manufacturer unit purposeMULTI V i, Outdoor Unit, 20HP, R410A
Evidence & conditions

Manufacturer specification

Exact manufacturer Product heading. Official current catalogue classes: VRF System. Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.

LG UK — ARUM200LTE6 manufacturer specifications
Manufacturer heating capacities at separate operating points56 kW; 63 kW; 215000
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. HEATING CAPACITY — Rated (kW): 56; HEATING CAPACITY — Max (kW): 63; HEATING CAPACITY — Max (Btu/h): 215000. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM200LTE6 manufacturer specifications
Manufacturer cooling capacities at separate operating points56 kW
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. COOLING CAPACITY — Rated (kW): 56. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM200LTE6 manufacturer specifications
Manufacturer electrical supply requirements50 Hz 380-415 V 3N~; 60 Hz 380 V 3N~
Evidence & conditions

Manufacturer specification

Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — #1: 50 Hz 380-415 V 3N~; POWER SUPPLY — #2: 60 Hz 380 V 3N~. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.

LG UK — ARUM200LTE6 manufacturer specifications
Enter a price you found

Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.

All product specifications →