
LG HN1616Y NB1 + HU121MRB U30
Compared with · LG HN1616Y NB1 + HU163MRB U30
- Manufacturer unit type and installation roleR32 Hydrosplit IWT, 3Ø, 16kW HN1616Y NB1 + HU163MRB U30 → R32 Hydrosplit IWT, 1Ø, 12kW HN1616Y NB1 + HU121MRB U30
- Heating-capacity declarations and operating conditions16 kW (A-7/W+55); 13.80 kW (A+2/W+35); 16.00 kW (A+7/W+35); 12.00 kW (A+7/W+55) → 12.00 kW (A+7/W+35); 11.00 kW (A+2/W+35); 11.00 kW (A+7/W+55)
- Electrical supply requirements380-415, 3, 50 → 220-240, 1, 50
- Cooling-capacity declarations and operating conditions16.00 kW (A+35/W+18); 16.00 kW (A+35/W+7) → 12.00 kW (A+35/W+18); 12.00 kW (A+35/W+7)
- Efficiency declarations, methods and operating conditionsCOP 2.5 (A-7/W+55); COP 3.60 (A+2/W+35); COP 4.80 (A+7/W+35); COP 2.80 (A+7/W+55); EER 4.00 (A+35/W+18); EER 2.50 (A+35/W+7); Seasonal space heating efficiency (ηS) (35℃ / 55℃) 179 / 135; SCOP (35℃ / 55℃) 4.55 / 3.45; Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Water heating efficiency (ηWH), average climate 120; Water heating eff. class, average climate A+ → Seasonal space heating eff. class (35℃ / 55℃) A+++/A++; Seasonal space heating efficiency (ηS) (35℃ / 55℃) 181 / 137; SCOP (35℃ / 55℃) 4.60 / 3.50; Water heating eff. class, average climate A+; Water heating efficiency (ηWH), average climate 120; COP 5.04 (A+7/W+35); COP 3.65 (A+2/W+35); COP 2.90 (A+7/W+55); EER 4.75 (A+35/W+18); EER 2,70 (A+35/W+7)
1 more difference
- Sound declarations and measurement basis43 dB(A); 63 / 60; 35 dB(A); 41 / 38 → 61 / 60; 43 dB(A); 39 / 38; 35 dB(A)
Same: Manufacturer refrigerant declaration R32
Compare side by sideFull comparison vs LG HN1616Y NB1 + HU123MRB U30
More details & evidence
Exact model: UK manufacturer configuration · HN1616Y NB1 + HU121MRB U30
Sources: 51 of 51 specifications cited.
Evidence · 100% source coverage
51/51 listed facts sourced. Checked date unavailable. This describes source coverage, not product quality or independent testing.
- Manufacturer facts
- 51
- Calculated from sources
- 0
- Independent measurements
- Not available
- Owner evidence
- Not available
- Conflicting facts
- None recorded
UK exact model
Market details
UK specification. UK availability not verified.
The specification region comes from this product’s reviewed variant record. It does not confirm local stock, warranty or delivery.
Check the manufacturer sourceWe have no current verified retailer listing for this exact variant in United Kingdom. A price you enter does not establish retailer availability.
Before you choose
- Manufacturer claims do not establish independently measured performance, current retailer stock or price. Unlisted specifications remain explicitly unknown.LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specifications
Key specification sources
Evidence & conditions
Manufacturer specification
Exact manufacturer Product heading. Official current catalogue classes: Heating Solution(AWHP). Indoor, outdoor, hydro and whole-package purposes are not substituted for one another.
LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specificationsEvidence & conditions
Manufacturer specification
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. NOMINAL CAPACITY AND COP (A+7/W+35) — Heating capacity (kW): 12.00; NOMINAL CAPACITY AND COP (A+2/W+35) — Heating capacity (kW): 11.00; NOMINAL CAPACITY AND COP (A+7/W+55) — Heating capacity (kW): 11.00. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specificationsEvidence & conditions
Manufacturer specification
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. REFRIGERANT — Type: R32. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specificationsEvidence & conditions
Manufacturer specification
Each declaration has its own manufacturer operating point, component, measurement method or electrical basis. They are not equivalent unqualified figures. POWER SUPPLY — Voltage, phase, frequency (V, Ø, Hz): 220-240, 1, 50. Heating/cooling output is separate from electrical consumption and supply. Sound power and sound pressure remain separately labelled in the original rows. No COP/SCOP/EER/SEER conversion, seasonal average or ranking is calculated.
LG UK — HN1616Y NB1 + HU121MRB U30 manufacturer specificationsEnter a price you found
Your total including delivery and taxes, for this exact variant in new condition. This remains your assumption.






